Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Add_workflow_for_techpubs
AUTH1UserResourceIdentifier{userKey=8a00a0c86820e56901685f374974002d, userName='null'}
JIRAIDAUTHSBX-114305
REV5UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cb8305e9, userName='null'}
REV6UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cb8305e9, userName='null'}
REV3UserResourceIdentifier{userKey=8a00a0c86cea5831016d24084ff50022, userName='null'}
REV1UserResourceIdentifier{userKey=8a00a0c863c32a720163c47764100001, userName='null'}


Excerpt

This object displays the call CDR configuration.

Note

Records are always written to the local disk.

On the SBC main screen, go to Administration > Accounting and Logs > Admin. The CDR Admin window is displayed.

Caption
0Figure
1Accounting and Logs - Edit Cdr Admin Window
Image Removed

Image Added

The fields displayed are:

Caption
0Table
1Edit Cdr Admin Window



Parameter

Description

cdrVerToGenerate

The SBC version on which the CDRs must remain formatted even after the SBC software is upgraded. The valid values for the configuration option are 0 or 10.1 for the SBC 10.1 release. The default value for the configuration is 0 (disabled). If the option is disabled, the CDRs are formatted according to the CAM version of the software release loaded on the SBC.

Note: The valid values list will change over time to support future releases.

  • 0 - (default
-
  • , indicates this control is disabled)
  • 10.1

Examples of how the configuration control works, if the users do not want to update the billing systems with every SBC upgrade:

Upgrade ScenarioAction and/or Effect

Upgrade from SBC 8.2 (or any old release) to 10.1 

The new control does not take effect.

Upgrade from SBC 8.2 ( or any old release) to 11.1 (or future releases later than 10.1) 

  • Baseline the SBC release and the Billing Systems to SBC 10.1.
  • Once the SBC and the billing system are on SBC 10.1, set the new configuration on the SBC to "10.1" from 0 (disabled).

If the configuration is set to the currently-loaded SBC software version (provided the current SBC loaded version is greater than or equal to 10.1) the CDR formatting is retained according to the selected SBC version across the upgrades.

Upgrade from SBC 10.1 to 11.1 (or future release later than 10.1) 

Set the new configuration to 10.1 from 0 (disabled) prior to the upgrade.

Fresh installation of the SBC (version greater than or equal to 10.1 ) 

  • Set the configuration before the SBC is commissioned to take the calls.
  • Ensure the configuration on the new SBCs are set to 10.1 as a part of the initial config load, before taking any traffic.

Example: you are planning to add more SBCs to a cluster already using the current feature (the SBC version is 11.1 and the CDRs are formatted to 10.1 by having the new config set to 10.1 on the SBCs).


Generate SIP Recording CDR

Enables or disables generation of CDRs for recording SIP calls.

disabled
  • Disabled (default)
enabled
  • Enabled

Generation Mode

The type of calls for which accounting records should be logged on this

Spacevars
0

series

series4
system:

origination
  • Origination (default)—Log accounting records for which this
    Spacevars
    0
series
  • series4
    system is the originating gateway.
destination
  • Destination—Log accounting records for which this
    Spacevars
    0
series
  • series4
    system is the destination gateway.
allcalls
  • All Calls—Log accounting records for all calls.
nonedisabled
  • None—Log no accounting records.
    For SIP and H323 calls, accounting records are generated for all calls (ingress and egress), unless this value is none.

Intermediate Acct State

Specifies whether Intermediate Accounting is Enabled or Disabled for the Node.

Options are:

  • Disabled (default)
enabled
  • Enabled

Intermediate Acct Interval

This configures the intermediate accounting interval in seconds.

Note: This object is only applicable when "sonusAcctIntAcctMode" is set to interval(1).

Second Stage Inherit First Stage

Enable flag to

allow second false

allow second stage accounting records for two stage calls to inherit fields from the first stage call.

Options are:

  • False (default)
true
  • True

Populate Non-ported LNP Numbers

Enable flag to

populate the

populate the Called Number Before Translation field in the accounting record for a number for which an LNP lookup was performed and lookup indicated that number has not been ported.

Options are:

  • False
  • True
  • false
  • true
    • (default)

    Intermediate Acct Mode

    Specifies the method by which intermediate records are generated.

    Options are:

    interval
    • Interval (default)—Generate an intermediate record for each "intermediateAcctInterval
    seconds
    • " (in seconds) throughout the call.
    telcordia
    • Telcordia—Generate an intermediate record whenever the call exceeds the configured "intermediateLongDurThreshold" value (in hours) and the "intermediateLongDurGenTime" (of day) is reached.

    Intermediate Long Dur Gen Time

    Specifies Octet string that identifies the GMT time to generate Telcordia Long Duration accounting records.

    The format is 00:00:00.0 where each field is:

    Code Block
    languagenone
    field octets   contents      range   
    ----- -------  ------------  -----
    1       1      hour          0..23
    2       2      minutes       0..59
    3       3      seconds       0..60 (use 60 for leap-second)
    4       4      deci-seconds  0..9


    Start Acct State

    Specifies whether Start Accounting is Enabled or Disabled for the Node.

    Options are:

    • Enabled (default)
    • Disabled
    Event Acct State

    Enable flag to generate EVENT records for OOD SUBSCRIBE, REFER, NOTIFY, REGISTER, OPTIONS, MESSAGE and PUBLISH event records. CDRs are logged when OPTIONS is relayed to the egress side.

    • Disabled (default)
    • Enabled
    Event Acct PSX Info State

    Log event records containing PSX information, such as PSX Congestion level, PSX Processing Time, Policy Response Call Type, PSX Billing Info, Route Label.

    • Disabled (default)
    • Enabled

    Intermediate Trap State

    Specifies whether a trap will be generated whenever an INTERMEDIATE record is generated.

    Options are:

    • Enabled
    • Disabled (default)
  • enabled
  • disabled

    Populate Remote GSX Info State

    Specifies whether a destination 

    Spacevars
    0series
    propagates its billing data to originating GSX for GW-GW calls.

    Options are:

    • Enabled
    • Disabled 
  • enabled
  • disabledenabled
    • (default)

    Early Attempt State

    Specifies whether or not to generate early ATTEMPT records. An early ATTEMPT record is associated with an early call disconnect, before the request is sent.

    Options are:

    • Enabled (default)
    -
    • Do not generate early ATTEMPT records.
    disabled -
    • DisabledGenerate early ATTEMPT records.

    Intermediate Long Dur Threshold

    Specifies the Accounting INTERMEDIATE Records Duration (in hours). Must be 1-24; default is 24. This parameter is only applicable when intermediate records mode is set to

    telcordiafalse

    Telcordia. The INTERMEDIATE record is generated for each call whose duration exceeds this threshold on long duration generation time.

    Send Egress CDR Info on Receipt

    Specifies whether or not to send the egress CDR information immediately after receiving and processing it.

    Options are:

    • False (default)
    true
    • True

    Populate IP TG Far End Switch Type

    Specifies whether or not to use Ingress Far End Switch Type passed down from PSX IP TG for SIP ingress calls.

    Options are:

    • Enabled
    • Disabled 
  • enabled
  • disableduint16
    • (default)

    Patch Ver

    Specifies a CAM patch version to roll the accounting file and print version-specific fields.

    Range: 0-255 / Default: 0

    Max Record Sequence Num

    Specifies the maximum length of the Record Sequence Number field in the CDR.

    Options are:

    • Uint16 (default)—16-bit record sequence number 0 to 65535.
    uint32
    • Uint32—32-bit record sequence number 0 to 4294967295.
    pagebreak