This task allows you to initiate a simple test call from Lync SBA (via the Front End Service itself) to the Sonus SBC 1000/2000

Spacevars
0product
 (SBC) gateway. The purpose of the test is to exercise the gateway's connectivity and call routing setup. This call is initiated by internally invoking the Test-CSPstnOutboundCall via the Lync powershell on the ASM.

Unlike the plain Testing a Call operation, this functionality initiates the call from the Lync SBA and not from within the Sonus SBC 1000/2000 itself.

Testing a Lync Call

Note

Before you begin: It is assumed that:

  1. The Lync SBA is deployed
  2. The Sonus SBC 1000/2000 and Lync are deployed with a PSTN Provider.
  1. In the WebUI, click the Tasks tab.
  2. In the left navigation pane, under the Lync™ Survivable Branch Appliance, click Test Lync™ Call.

    Panel
    borderStylenone

    Caption
    0Figure
    1Test Lync Call

    Image Removed

    Image Added

  3. Enter the Destination PSTN Phone Number and the optionally the SIP URI Address

    Panel
    borderStylenone

    Caption
    0Figure
    1Enter Test Lync Call Information

    Image Removed

    Image Added

  • The PSTN Phone Number is mandatory and should be in an E.164 format matching the Lync default dial plan.
  • The SIP URI Address is an optional parameter. If used, it must be a valid user ID configured on the Lync server.

...

  • Click OK.

Expected Outcome

The system will place a call from the Lync SBA to the Sonus SBC 1000/2000 and expect the call to be routed via the PSTN number provided. Once the number is physically answered by a user, the call will automatically hang up and the webUI will return success. Note that no audio will be sent from the Lync SBA - the intent is to simply test the signalling and routing.

If the phone is never answered it will eventually timeout and return an error. Similarly, an error will immediately return if either the Lync SBA and/or Sonus SBC 1000/2000 have a misconfiguration or routing problem.