Info | ||
---|---|---|
| ||
For optimal performance, refer to Performance Tuning of VMs page before preceding with the information in this section. |
Install Linux Vanilla flavor 7.2
Configure the Linux Vanilla flavor kernel to support IOMMU.
Expand | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||
|
...
Log on to the Host IP as root user.
To know the maximum number of virtual functions a physical function can support, execute below command:
Code Block |
---|
cat /sys/class/net/eth3/device/sriov_totalvfs |
On a host machine (compute node), create the required number of virtual functions via the PCI SYS interface. Execute below command:
In this example, we create 8 virtual functions. The total number of virtual functions is based on the requirements.
Code Block |
---|
echo "echo '8' > /sys/class/net/eth3/device/sriov_numvfs" >> /etc/rc.local |
Reboot the system.
To verify devices exist and to attach VM:
To list the newly added Virtual functions attached to the network device, execute below command:
Example: Intel I350
Code Block |
---|
lspci | grep I350 01:00.0 Ethernet controller: Intel Corporation I350 Gigabit Network Connection (rev 01) 01:00.1 Ethernet controller: Intel Corporation I350 Gigabit Network Connection (rev 01) 01:00.2 Ethernet controller: Intel Corporation I350 Gigabit Network Connection (rev 01) 01:00.3 Ethernet controller: Intel Corporation I350 Gigabit Network Connection (rev 01) 01:00.4 Ethernet controller: Intel Corporation I350 Gigabit Network Connection (rev 01) 01:00.5 Ethernet controller: Intel Corporation I350 Gigabit Network Connection (rev 01) 01:00.6 Ethernet controller: Intel Corporation I350 Gigabit Network Connection (rev 01) 01:00.7 Ethernet controller: Intel Corporation I350 Gigabit Network Connection (rev 01) 01:10.0 Ethernet controller: Intel Corporation I350 Ethernet Controller Virtual Function (rev 01) 01:10.1 Ethernet controller: Intel Corporation I350 Ethernet Controller Virtual Function (rev 01) 01:10.2 Ethernet controller: Intel Corporation I350 Ethernet Controller Virtual Function (rev 01) 01:10.3 Ethernet controller: Intel Corporation I350 Ethernet Controller Virtual Function (rev 01) 01:10.4 Ethernet controller: Intel Corporation I350 Ethernet Controller Virtual Function (rev 01) 01:10.5 Ethernet controller: Intel Corporation I350 Ethernet Controller Virtual Function (rev 01) 01:10.6 Ethernet controller: Intel Corporation I350 Ethernet Controller Virtual Function (rev 01) 01:10.7 Ethernet controller: Intel Corporation I350 Ethernet Controller Virtual Function (rev 01) |
To filter the Intel I350 network device from the list of available host devices use 01, execute below command:
Code Block |
---|
virsh nodedev-list | grep 01 pci_0000_01_00_0 pci_0000_01_00_1 pci_0000_01_00_2 pci_0000_01_00_3 pci_0000_01_00_4 pci_0000_01_00_5 pci_0000_01_00_6 pci_0000_01_00_7 pci_0000_01_10_0 pci_0000_01_10_1 pci_0000_01_10_2 pci_0000_01_10_3 pci_0000_01_10_4 pci_0000_01_10_5 pci_0000_01_10_6 pci_0000_01_10_7 |
To get device details:
Noteinfo |
---|
Follow step 6 and 7 for other packet interface as well. |
The pci_0000_01_00_0 is one of the Physical Functions and pci_0000_01_10_0 is the first corresponding Virtual Function for that Physical Function.
To get advanced output for both devices, execute below command:
Code Block |
---|
virsh nodedev-dumpxml pci_0000_01_10_0 <device> <name>pci_0000_01_10_0</name> <path>/sys/devices/pci0000:00/0000:00:03.0/0000:01:10.0</path> <parent>pci_0000_00_03_0</parent> <driver> <name>igbvf</name> </driver> <capability type='pci'> <domain>0</domain> <bus>1</bus> <slot>16</slot> <function>0</function> <product id='0x1520'>I350 Ethernet Controller Virtual Function</product> <vendor id='0x8086'>Intel Corporation</vendor> <capability type='phys_function'> <address domain='0x0000' bus='0x01' slot='0x00' function='0x2'/> </capability> <iommuGroup number='94'> <address domain='0x0000' bus='0x01' slot='0x10' function='0x2'/> </iommuGroup> <numa node='0'/> <pci-express> <link validity='cap' port='0' speed='5' width='4'/> <link validity='sta' width='0'/> </pci-express> </capability> </device> |
This example adds the Virtual Function pci_0000_01_10_0 to the virtual machine. Note the bus, slot and function parameters of the Virtual Function is required for adding the device. For example, copy these parameters into a temporary XML file, such as /tmp/new-interface.xml.
Code Block |
---|
<interface type='hostdev' managed='yes'> <source> <address type='pci' domain='0' bus='1' slot='16' function='0'/> </source> </interface> |
Before going to add the Virtual Functions to the virtual machine, we must detach those virtual functions from Host machine.
Code Block |
---|
virsh nodedev-detach pci_0000_01_10_0 |
To add the Virtual Function to the virtual machine, execute below command. This attaches the new device immediately and saves it for subsequent guest restarts.
Noteinfo |
---|
The MyGuest indicates the Virtual Machine name. |
Code Block |
---|
virsh attach-device [MyGuest] /tmp/new-interface.xml --config |
Noteinfo |
---|
Using the --config option ensures the new device is available after future guest restarts. |