Type: WARNING/CRITICAL

Description

This trap alarm indicates the SBC hard disk space is low.

    • If disk becomes 75% full, the SBC issues this trap with a severity of "warning".
    • If disk becomes 90% full, the SBC issues this trap with a severity of "critical".

has reached 75% capacity. Once the disk usage is reduced to 70% full, the sonusCpSystemLocalDiskSpaceOkNotification trap alarm is issued.

Repetition

None

Event Codes

 sonusAlarmNodeID
sonusAlarmLevel
sonusAlarmSequenceId
sonusAlarmTime
sonusAlarmDescription
sonusCpSystemAdminName
sonusCpSystemServerName
sonusCpSystemHardDiskNumber
sonusCpSystemDiskPartition
sonusCpSystemDiskSpaceUsedPct

Instance FieldsNone

sonusCpSystemAdminName
sonusCpSystemServerName
sonusCpSystemHardDiskNumber
sonusCpSystemDiskPartition
sonusCpSystemDiskSpaceUsedPct

Action

Take immediate action to free up disk space.

Impact

If the disk becomes 95% full, the SBC application shuts down.

Clearing

Manual