This section describes the method to upgrade the 

Spacevars
0series2
BMC and BIOS firmware. The BMC and BIOS images are bundled into a single firmware package "firmware-7X00-V<release>.img".

Include Page
Screenshots_with_outdated_sw_fw_versions
Screenshots_with_outdated_sw_fw_versions

The following procedure describes how to upgrade the firmware from the BMC web GUI.

  1. Log on to the SBC BMC GUI.

    Caption
    0Figure
    1BMC Login Screen

    Image Modified

    The BMC main screen is displayed.

    Caption
    0Figure
    1BMC Main Screen

    Image Modified

  2. Click Firmware Update. The Firmware Update screen is displayed.

    Caption
    0Figure
    1Firmware Update Screen

    Image Modified

  3. Click Browse, and from the Open dialog browse to and

...

  1. select the firmware-7X00-V<release>.img firmware image. To determine the exact firmware version,

...

  1. refer to SBC Release Information for

...

  1. the current release notes.

    The chosen file displays next to the Browse button.

    Caption
    0Figure
    1Browsing Firmware Image

    Image Modified

  2. Click Upload.

    Info

...

  1. titleNote

    The firmware image is a

...

  1. 26 MB file and takes few minutes to upload based on the network. 

  2. Once

...

  1. the upload completes, the Firmware

...

  1. Update screen displays the firmware images and

...

  1. versions.

    Caption
    0Figure
    1Uploading Firmware Image

    Image Modified

    Info

...

...

  1. titleNote

...

  1. In the previous screen, if both the Old Version and New Version are same, then the update status displays as "No". 

  2. Click Confirm to continue. The upgrade progress bar displays on the screen.

    Info

...

  1. titleNote

    This is a service-affecting procedure and will power off the host side of the SBC. 

    Include Page
    _Host Shutdown Failure During BMC Upgrade
    _Host Shutdown Failure During BMC Upgrade

  2. After the firmware upgrade

...

  1. completes, the following

...

  1. dialog displays.

...

  1. Click OK to close the message.

    Caption
    0Figure
    1Completing Firmware Upgrade

    Image Modified

    Info

...

  1. titleNote

    Once the upgrade completes, the BMC and host

...

  1. reboot automatically. Verify that the SBC starts and sync with its peer server before proceeding further. 

  2. Close the SBC BMC GUI.

  3. Clear the browser cache and log on to the BMC GUI again.

  4. Log on to the SBC BMC GUI again.

...

  1. The SBC BMC

...

  1. prompts you to change the password after a successful upgrade.

    Info

...

  1. titleNote

    This change is applicable only when the

...

  1. BMC is upgraded to version 03.13.00 and later versions. 

    Caption
    0Figure
    1Change Default Password window

    Image Modified

  2. Click OK to proceed. The User Management window is displayed.

    Info

...

  1. titleNote

    You have an option to cancel the action. If

...

  1. canceled, the password remains the same as the default password and you are allowed to continue to work on the BMC. However, the warning message is displayed again on your next

...

  1. login to BMC. This reminder continues

...

  1. until the password is changed.

...

  1. Refer to Changing the BMC Password for the procedure to change the password.

  2. Verify the upgraded version in the BMC main screen and ensure the BIOS and BMC versions match the versions listed in the release notes.

 

Info

...

titleNote

For HA configuration, refer to Upgrade Flows for guidance. 

Pagebreak