Type: CRITICAL

Object ID1.3.6.1.4.1.2879.2.8.1.2.1.2.0.1

Description

This alarm indicates a server module redundancy switchover has occurred. The standby server module has become active.

The previous active server module

,

and group information are included. For 1+1 the redundancy model, there is no group name.

Repetition

None

Event Codes

Objects

  • sonusCpSystemServerName
  • sonusCpRedundPrevActiveServerName
  • sonusCpRedundancyServicesGroupName

Instance Fields

None

Action

None

Impact

Loss of redundancy occurs for the particular redundancy group. Some transient calls may be lost

as a result of

due to switchover, but no lasting (normally) impact

to

on overall system operation occurs.

Clearing

Automatic; sonusCpRedundGroupFullRedundancyNotification
Manual