Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


Excerpt

Use the CFT window to configure the ingress confirmation tone for a Signaling Profile.

To View and Edit CFT

On the SBC main screen,

...

use one of the following paths:

  • Configuration > Profile Management > Category: Signaling Profiles > Signaling Profile > Ingress > CFT

...

  •  
  • All > Profiles > Signaling > Signaling Profile > Ingress > CFT

Select a Signaling Profile from the drop-down list. The CFT window is displayed.

...

Signaling Profile - Ingress - CFT

Image Modified

Use the following table to select a value  and then click Save.

...


Ingress CFT Parameters:

ParameterDescription
Send CFT Information

When this check box is selected

...

for SIP calls, the egress SBC

...

sends confirmation tone (CFT) information (whether the call is considered On-Net or Off-Net) to the SIP server.

...

 

  • Disable (default)
  • Enable
Cft Info For Early Backward Message

Specifies the default value for the confirmation tone information when routes are absent from the policy response for SIP calls.

...

  • Offnet
  • Onnet
  • Unknown (default)

Note: This option appears when you

...

enable Send CFT Information.