Page History
Add_workflow_for_techpubs | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Panel | ||||
---|---|---|---|---|
In this section:
|
Tooltip | ||
---|---|---|
| ||
Slots 1 through 4 of the
Spacevars | ||
---|---|---|
|
- Each DSP-LC card contains 28 DSP Devices.
- Each DSP Device contains 8 Core Signal Processors.
- Each Core Signal processor can handle many simultaneous media streams of processing.
The DSP-LC product code is SBC-7000-DSP-LC.
Caption | ||||
---|---|---|---|---|
| ||||
Parts and Tools Required
Tooltip | ||
---|---|---|
| ||
The following items are needed to replace a DSP-LC card:
- Electrostatic discharge (ESD) strap
- Replacement DSP-LC
- A #2 Phillips-head screwdriver
Include Page | ||||
---|---|---|---|---|
|
Include Page | ||||
---|---|---|---|---|
|
Replacing the DSP-LC Card
To replace aReplace DSP-LC
card:Card
Ensure that the affected SBC is in standby node.
Run '
sbxstop
' on the standby node to to shut down the application.Once the application on the standby node is stopped, perform the card swap. You can check the status of the application using the '
Disable the DSP-LC card via EMA GUI (All > System >Daughter Board Admin > State (Disabled)).sbxstatus
' command Removing a disabled DSP card does not bring down the rest of the node (hot swappable).Note
Removing an enabled DSP card is a hot pluggable action (the node restarts, which means that it stops providing service; this will cause a switchover to a HA peer, if present).
- Attach an Electrostatic Discharge wrist strap by using the ESD grounding point on the back panel of the chassis (see Connecting Electrostatic Discharge Wrist Strap on SBC 7000 for details).
Unscrew the thumb screws using #2 Phillips-head screwdriver, open the release levers on each side and pull the DSP-LC card.
To replace, insertCaption 0 Figure 1 SBC 7000 DSP-LC card pulled out - Align the new DSP-LC card
- with the correct slot and gently push it
- forward until it is fully inserted.
- Close the release levers.
- Tighten the thumb screws using a #2 Phillips-head screwdriver.
- Start the application on the standby node using the '
sbxstart
' command. As the SBC application starts, the DSP -LC card via EMA GUI (All > System >Daughter Board Admin > State (Enabled))card will reprogram its FPGA if it is needed.
Field Programmable Gate Array
The DSP-LC module includes a Field-Programmable Gate Array (FPGA) that may occasionally require reprogramming. Generally, reprogramming is fully autonomous and occurs during the application start process. If the FPGA update is required, expect an additional 1-2 minutes added per DSP-LC card present to the length of a normal application start process. For some older versions of the FPGA image, reprogramming requires user intervention.
Log messages pertaining to FPGA reprogramming are stored in the following files:
- sbx_start.log_<timestamp> file located in
/var/log/sonus/sbx/openclovis
directory. This file contains all logs related to system startup as well as a log of other scripts that call this FPGA reprogramming utility. /var/log/messages
file.
If the following error is logged, refer to the Method of Procedure to Upgrade SBC 7000 DSP-LC FPGA to update the DSP-LC card.:
Code Block |
---|
Dec 26 18:10:36 /opt/sonus/sbx/scripts/fpgaUtil.pl[26697]: Dec 26 18:10:36 /opt/sonus/sbx/scripts/fpgaUtil.pl[26697]: ERROR - DSP-LC FPGA Version does NOT support Host programming Dec 26 18:10:36 /opt/sonus/sbx/scripts/fpgaUtil.pl[26697]: Current Revision: 0x00000014 Dec 26 18:10:36 /opt/sonus/sbx/scripts/fpgaUtil.pl[26697]: Minimum Revision: 0x00000015 Dec 26 18:10:36 /opt/sonus/sbx/scripts/fpgaUtil.pl[26697]: Dec 26 18:10:36 /opt/sonus/sbx/scripts/fpgaUtil.pl[26697]: |
CRU Storage
Tooltip | ||
---|---|---|
| ||
All
Spacevars | ||
---|---|---|
|
- Humidity must be less than 95% (non-condensing).
- Temperature must be between -40C and +70C.
Include Page | ||||
---|---|---|---|---|
| ||||