To configure the BMC for remote access:
Enter "https://169.254.77.1" into a supported browser (Firefox or IE) to connect to the BMC GUI.
Info title Note The SBC 5400 is delivered with sample self-signed X.509 certificates. Please be aware that even though these sample certificates will allow you to use HTTPS to access the SBC 5400 from BMC and EMA interfaces, using this protocol with the sample certificates is not a truly secure access method. If your organization requires a more secure access, see Generating PKI Certificates.
Log on to the
BMC GUI.Spacevars 0 model5 The
BMC main screen is displayed.Spacevars 0 model5 Click Configuration > Network tab.
Caption 0 Figure 1 BMC Configuration Path
The Network Settings screen is displayed.Caption 0 Figure 1 BMC Network Settings Screen - Configure the IPv4 Address, Subnet Mask and Default Gateway network settings. Else, select Use DHCP to obtain the IPv4 configuration details automatically.
Select Enable JViewer and/or Enable SSH options under the “Security” settings depending upon your security requirements. It is recommended to leave the Enable IPMI option disabled.
Note title Caution Enable IPMI is a service impacting operation. This reboots both the BMC and the host server. The changes to any of the three security items does not occur until the Save button is clicked.
Include Page _IPMI_Security_Vulnerability _IPMI_Security_Vulnerability Click Save.
Caption 0 Figure 1 Configuring BMC Network Caption 0 Figure 1 Rebooting BMC for Enabling IPMI
Click Ok to reboot the BMC.Once you click Save, the following warning message appears:
Caption 0 Figure 1 BMC Network Configuration Warning Message Click OK to proceed. A pop up window appears stating that the security configuration is successfully completed.
Caption 0 Figure 1 Successful Configuration Message - Click OK to complete the process.
- Disconnect the PC/Laptop from the FSP.
Connect the FSP of
to allow remote access of the BMC.Spacevars 0 model5 Caption 0 Figure 1 Field Service Port
Info | ||
---|---|---|
| ||
Once the real BMC address is configured, you cannot access the pre-configured BMC address. Clear the browser cache (browser-specific) and open a new browser session to reflect the changes. |