Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


Panel

In this section:

Table of Contents
maxLevel3


Overview

Tooltip
tipUse ESD protective device

Spacevars
0model5
systems configured for DC power can accommodate dual redundant DC power supplies, as shown in the following figure DC Power Supply.

The DC power supply is a Customer Replaceable Unit (CRU). The product code is SBC-5400-PSUDC. AnchorDC Power SupplyDC Power Supply

Caption0Figure1

DC Power Supply

Image Modified


In a dual redundant power supply configuration, the Power Supplies power supplies are hot-swappable meaning that . You can replace a power supply may be replaced without powering down the the

Spacevars
0model5
platform (provided that one power supply is operational).

 


Table
Note
titleImportant
Before replacing a power supply in a redundant power supply configuration, verify the status of the redundant power supply. The “POK” LED status must be “solid green”. Removing the power supply when the redundant power supply does not show a solid green status, may cause the system to power down. Contact
Spacevars
0company
Customer Support if required.
Caption
01

SBC 5400 DC

power supply states

Power Supply States

Power Supply ConditionLED States (Green/Amber)
No DC Power to all PSUOFF
DC present/Standby Outputs ON, Main Output OFF Blinking Green
Power supply DC Outputs ON and OKSolid Green
Main Output Failure (OCP, OVP, UVP)Blinking Amber
Fan Fail, OTP, Standby Output OCP/UVPSolid Amber

Parts and Tools Required

  • Electrostatic discharge (ESD) strap
  • Replacement DC supply.
  • A #2 Phillips-head screwdriver
  • Torque driver with #2 Phillips bit
  • Voltmeter
 


Note
The chassis is shipped with one power supply, unless a second power supply is added at the time the order is placed.


Note

To prevent damage from electrostatic discharge, an ESD strap is provided in the accessory kit. Refer to Connecting ESD Wrist Strap to install it.

 

Replacing a Power Supply

Perform the following procedure to replace a power supply:

  1. Attach an Electrostatic Discharge (ESD) wrist strap to the ESD grounding point on the back of the chassis, and place the other end around your wrist (see refer to Connecting Electrostatic Discharge ESD Wrist Strap, for details).
  2. Disconnect -48VDC power to the DC power supply being replaced by shutting off circuit breaker or removing fuse on facilities power distribution panel or similar operation.
  3. Verify the POK LED is off on the DC power supply being replaced.
  4. Ensure that power is no longer present on power cables using a voltmeter.
  5. Remove clear plastic protective cover on terminal strip.

    Caption0Figure


    1Removing the plastic protective cover


    Image Modified


  6. 1Disconnecting the RTN and -48V connections

    Disconnect RTN and -48V connections by loosening two terminal strip screws using the #2 Philips screwdriver.

    Caption0Figure



    Image Modified


  7. Disconnect power supply ground connection by removing the screw securing the green chassis ground wire to the DC power supply using the #2 Philips screwdriver.
  8. Disengage the DC power supply latch by moving the latch to the left.
  9. Pull on the loop handle to slide the DC power supply out of the SBC chassis.
  10. Install the replacement DC power supply into the
    Spacevars
    0product
    chassis by sliding it forward until the latch clicks in place.
  11. Reconnect the green power supply ground wire to the DC power supply using the torque driver supply and tighten the screw to 13.9 in/lb.
  12. Reconnect the RTN and -48V cables to the terminal strip screws and tighten to 13.9 in/lb using the torque driver.
  13. Reinstall the clear plastic protective cover on the terminal strip.
  14. Apply power to the DC power supply by turning the circuit breaker or installing the fuse on facilities power distribution panel or similar operation.
  15. Verify that the POK green LED on the newly-replaced power supply is solid green.
  16. From the application, verify that no power supply alarms are generated. 

CRU Storage

Tooltip
tipESD protective device

All

Spacevars
0model5
CRUs are shipped in electrostatic discharge bags and should be handled using appropriate ESD precautions.

The storage environment for these CRUs is:

  • Humidity must be less than 95% (non-condensing)
  • Temperature must be between -40C and +70C.

Include Page
_ESD_footnote
_ESD_footnote