Use the following procedure to configure the system once the initial install has completed. The
It is assumed that before you execute the procedure presented in this page, you have completed the following tasks:
...
Info |
---|
|
If your system is licensed for PCE, the initial configuration must be done on all slots. If not, execute the initial configuration on one ROUTING_MGMT VM. All other VMs will be updated accordingly. |
After you have completed the initial configuration procedures described in this section, if required, you can change the default Point Code Emulator (PCE) NA values to any unique value from 1 to 99. The default PCE NA settings are recommended unless they are already in use by existing configurations and the PCE support creates a conflict. The PCE supports Basic and Enhanced licensing options. A Basic license allows for one public (NA 1) and one private (NA 2) network. The Enhanced license allows for one public (NA 1) network and two private networks (NA 2 and NA 3). The Enhanced PCE is used in networks that are migrating traffic from an existing switch to a new switch. In this configuration, the existing switch and the new switch may have the same Local Point Code (LPC) and are able to transmit SS7 signaling to one another.
For more information about PCE, refer to the appropriate section in the SS7 Application Guide 2.
...
initial configuration procedure must be executed using the Menu UI. For detailed information about the Menu UI, refer to Web UI and Menu UI Guide.
...
...
- before executing the following procedure.
...
...
Multiexcerpt |
---|
MultiExcerptName | Execute Initial Config Procedure |
---|
|
StartFrom the Main Menu, select Set Initial Configuration, and press ENTER. Image Modified
- Enter y, and press ENTER.
- If your system is not licensed for PCE, the system automatically executes the initial configuration procedure. Go to step 5.
- If it is detected that PCE has been licensed on this system, the following screen is displayed. Go to step 3.
Image Modified
- If your system is licensed for PCE, do one of the following:
Only one DSC
|
...
system is running PCE. Select 3 - Not as a Mated Pair. Go to step 4.
|
...
...
systems are running PCE. Enter 1 - Mated Pair as Node 1, and press ENTER.
|
...
...
Press ENTER. The system automatically executes the initial configuration procedure. Tip |
---|
| After the system executes the initial configuration for Node 1, you must execute this procedure for Node 2 in the mated pair configuration. Make sure to select 2 - Mated Pair as Node 2 and enter the IP addresses you configured for Node 1. |
You are prompted to decide whether EMS access should be enabled on the system that you are configuring.
|
...
Image Added
Do one of the following. - If you want to have EMS access enabled, press y, and press ENTER, and go to step c.
- If you do not want EMS access enabled, go to step d.
- If you pressed y
|
...
- and ENTER in step a, the system enables EMS access and executes the initial configuration procedure, and restarts the Web UI.
|
...
- Image Added
If you do not want to enable EMS access, enter n, and press ENTER. A message appears informing you that EMS access was not enabled (EMS snmp rw community string was not activated), and the system continues to automatically execute the initial configuration procedure and restart the Web UI.
Tip |
---|
| If, at a later time, you want to enable EMS access, refer to Enabling EMS. |
Tip |
---|
| You have to wait approximately five minutes before you can access the Main Menu in Web UI after the system completes the execution of the initial configuration procedure. |
|