Add_workflow_for_techpubs | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Type: MINOR
Object ID | 1.3.6.1.4.1.2879.2.10.1.1.1.0.95 | ||
Description | This alarm indicates that the registration cleared due to no response for CRLF from AS.is only used in conjunction with a deployment that has a unique TLS connection to the registrar for each user. The alarm is generated on a per user basis, when the registrar fails to respond to a CRLF ping from the SBC, or if there is an SBC switchover. | ||
Repetition | Generated on a per user basis. The instance fields identify the unique user. | Repetition | TBD |
Event Codes |
| ||
Instance Fields |
| ||
Action | TBD | ||
Impact | TBD | ||
The SBC may have switched over, or the registrar may not be working correctly. Check and resolve the issue. | |||
Impact | The SBC removes the registration details of the user. You must register with the SBC/registrar again before making or receiving calls. | ||
Clearing | Manual | Clearing | TBD |