Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Type: CRITICAL

Object ID

1.3.6.1.4.1.2879.2.10.1.1.6.0.2

Description

This alarm is

Generated

generated when Accounting Records are no longer being generated on the Node.
Possible causes:

  • A change to the accounting configuration.
  • Errors in the logging mechanism, such as file logging errors.

When the reason specified for accounting out-of-service is an event logging error, and then

Repetition

None

Event Codes

  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescription
  • sonusAcctOutOfServiceReason

Instance Fields

None

Action

Examine the SYS event logs on the Node

should be examined

to obtain further information about the event logging failure

.

Repetition

None

Event Codes

sonusAcctOutOfServiceReason—The Reason Node is Out

when the reason specified for accounting out-of-

Service. Values include:
configChange(1)
eventLoggingError(2)

Instance Fields

None

Action

None

service is an event logging error.

Impact

No Call Detail Records (CDRs) are generated

Clearing

Automatic, sonusSbxCallAccountingInServiceNotification