Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


 

This section describes upgrading the

Spacevars
0product
application in a standalone or HA configuration using EMA. Beginning with the 5.0 release, Platform Manager is integrated into EMA and referred to as EMA Platform Mode. 

Info
titleNote

Prior to performing an application upgrade to the 7.1.0 release, upgrade the SBC firmware to the latest version on both active and standby SBCs in an HA pair.

  • Refer to the release notes for the latest firmware version.
  • To upgrade the firmware, refer to Upgrading BMC Firmware.
  • Stop the SBC application on the already upgraded active node, prior to upgrading the standby node. Failure to stop the application on the already upgraded node results into inability to upgrade the standby.

...

Info
titleNote

Ensure that the following requirements are met prior to performing an upgrade or LSWU to the 07.01.xx release:

...

Info
titleNote

The BIOS firmware upgrade is not part of the SBC application upgrade in

Spacevars
0series2
platforms. Refer to Upgrading SBC 7000 Series Firmware for more information. 

The following procedure describes

Spacevars
0series4
application upgrade from version 07.00.00R000 to 07.01.00R000 release using upgrade using the EMA (non-LSWU):

  1. Download the SBC application package from the Ribbon Support Portal to your local folder on a PC or remote server. Refer to Downloading Software from the Ribbon Support Portal.
  2. Validate the SBC md5 checksum using the checksum calculator. See Validating MD5Sum with 'Checksums Calculator' for guidance.
  3. Launch EMA.

  4. Navigate to Monitoring > Dashboard > System and Software Info to verify the software and HA peer status for both active and standby servers.

    Caption
    0Figure
    1System and Software Info Screen for Active Server


    Caption
    0Figure
    1System and Software Info Screen for Standby Server


  5. Navigate to Administration > System Administration > File Upload to upload the SBC application package to the active and standby SBC servers.

    1. Click File Upload tab.

      Caption
      0Figure
      1File Upload Screen


    2. Click Add Files to Queue.

    3. Browse for the SBC application package files in the File Upload screen and click Open 

      note

      A new "qcow2" image file is added to the list of upgrade files for upgrade to 6.0.0 R0 and later releases.

      For example: "sbc-V07.01.00R000-connexip-os_06.01.00-R000.qcow2".

      Caption
      0Figure
      1Selecting SBC application package

        

    4. The files are listed in the Upload Queue section. Click Upload All Files. The file upload starts.

      Caption
      0Figure
      1Files on SBC

       

       


    5. Repeat steps "a" through "e" for  the standby SBC server.

  6. Stop the application on  on the active server using Administration > System Administration > Platform Management > Stop SBC Application.
    Stopping the application is a service-affecting operation.

    Caption
    0Figure
    1Stopping SBC Application in Active Server


  7. Stopping the application is a service-affecting operation. Click OK to continue the stop operation.

    Caption
    0Figure
    1Confirming Stop SBC Application

    The application

    is stopped

    stops on the active server.

  8. Launch the EMA Platform Mode on the Standby standby server.

    Info
    titleNote

    Once the active server (WFDSBC01a) is stopped, the standby server (WFDSBC01b) automatically becomes active. 


  9. Stop the application on the Standby standby server using Administration > System Administration > Platform Management > Stop SBC Application.
    Stopping the application is a service-affecting operation.

    Caption
    0Figure
    1Stopping SBC Application on Standby Server


  10. Stopping the application is a service-affecting operation. Click OK to continue the stop operation.

    Caption
    0Figure
    1Confirming Stop Application

    The application

    is stopped

    stops on the

    Standby

    standby server.

    Caption
    0Figure
    1Application Stopped on Standby Server


    Info
    titleNote

    If you are upgrading an SBC SWe deployment, before starting the upgrade of the active instance, shut down or power-off the standby instance from the host.


  11. From the EMA of the initial active server (WFDSBC01a), Navigate navigate to Administration > System Administration > Software Install/Upgrade.

  12. Select the SBC Package Name to upgrade, and click Standalone Software Upgrade.

    Info
    titleNote

    Because you are performing a non-LSWU upgrade and both the active and standby SBCs are down, it is considered a standalone upgrade even for an HA pair. 


    Caption
    0Figure
    1Selecting SBC Package

     

     

    The  The signature file of the SBC package verifies the integrity of the package contents before proceeding with the SBC installation.

    Caption
    0Figure
    1Verifiying Package Integrity

     


  13. Click Start Upgrade.

    Caption
    0Figure
    1Selecting Offline Upgrade

     

     

    The  The upgrade process starts on the active server (WFDSBC01a) and displays the upgrade status in the Upgrade Log section.

    Caption
    0Figure
    1Performing pre-install checks and DB install


    Info
    titleNote

    You may lose connectivity to the browser session when the server reboots. 


    Info
    titleNote

    This process takes approximately 45 minutes to complete on a single server. 


    Warning

    Once the upgrade is successful, clear the browser cache prior to accessing the SBC EMA.


  14. Log on to EMA using the default credentials.

    Caption
    0Figure
    1Logging On to EMA Platform


    Caption
    0Figure
    1Logging On to EMA Platform


  15. Verify the SBC installation status on the Administration > System Administration > Software Install/Upgrade screen.

    Caption
    0Figure
    1Continuing the SBC Upgrade

    Wait until the SBC upgrade is complete.

  16. Verify the SBC application status on the Administration > System Administration > Platform Management screen.

    Caption
    0Figure
    1Verifying Active SBC Status


    Info
    titleNote

    Once all the SBC processes start running, continue upgrading the Standby standby SBC server. 


    Note

     If upgrading your SBC from a release prior to 57.1.x, stop the application on the active server using Administration > System Administration > Platform Management > Stop SBC Application before proceeding to the next step.


  17. Follow steps 13 11 through 18 16 to perform an upgrade on the standby server (WFDSBC01b).

    Info
    titleNote

    If you are upgrading an SBC SWe deployment, power-on the standby instance from the host before returning to step 11.


  18. Verify the SBC application status on the Administration > System Administration > Platform Management screen.

    Caption
    0Figure
    1Verifying Standby SBC Status


  19. Verify the firmware, ConnexIP OS and SBC application versions in Monitoring > Dashboard > System and Software Info.

    Caption
    0Figure
    1System and Software Information for Active Server


    Caption
    0Figure
    1System and Software Information for Standby Server


  20. Verify the system sync status is in Sync Completed state in All > System > Sync Status.

    Caption
    0Figure
    1System Sync Status

     

     


    Pagebreak