Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: fixed issue with graphic inside a warning which did not appear properly in pdf.
Panel

In this section:

Table of Contents
maxLevel4

Info
iconfalse

Related articles:

 

From the SBC main screen, navigate to All > Profiles > Signaling > Atprofile.

The window Atprofile appears, showing the Atprofile List table.

Caption
0Figure
1Atprofile window with frame Atprofile List

Image Added

 

The parameter in the table Atprofile List are:

Caption
0Table
1Parameters: Atprofile List
 ParameterDescription
ID

An unique identifier for the Access Transfer profile.

 

Create a new Atprofile

To create a new Atprofile, click the button New Atprofile.

Caption
0Figure
1New Atprofile

Image Added

 

The frame Create New Atprofile appears. Give an ID to the new Atprofile.

Caption
0Figure
1Create New Atprofile

Image Added

 

Click Save to save the new Atprofile. Click Undo Edits to undo all changes since the last saved configuration.

On successful creation of the Atprofile, the Success message appears.

Caption
0Figure
1Successful creation of new Atprofile

Image Added

 

Copy an Atprofile

To copy an Atprofile, select the Atprofile from the list displayed.

Caption
0Figure
1Select Atprofile from list

Image Added

 

The selected Atprofile is displayed in the frame Atprofile. It appears below the frame Atprofile List.

Caption
0Figure
1Display selected Atprofile

Image Added

 

Click the button Copy Atprofile.

Caption
0Figure
1Copy Atprofile

Image Added

 

The frame Copy Selected Atprofile appears.

Caption
0Figure
1Copy Selected Atprofile

Image Added

 

All the fields of the frame Copy Selected Atprofile, except the field ID, have values that are same as that of the Atprofile selected for copying.The field ID has to be supplied with a value which is different from the ID of the Atprofile selected for copying.

Caption
0Figure
1All fields of Copy Selected Atprofile

Image Added

Info
titleNote:

By default, the field Access Transfer Policy Profile Type is set to ATCF. The figure above, with the title All Fields of Copy Selected Atprofile, illustrates the default scenario.

However, if the field Access Transfer Policy Profile Type is set to EATF, the fields corresponding to the object Feature Capability Indicator changes, as illustrated below.

Caption
0Figure
1Access Transfer Policy Profile Type is set to EATF

Image Added 

 

The fields in the frame Copy Selected Atprofile are:

Caption
0Table
1Parameters: Copy Selected Atprofile
 FieldOptions/Possible ValuesDescription
IDN/AThe name/identity to be given to the Atprofile, whose configuration matches fully or partly with the selected Atprofile.
Access Transfer Policy Profile Type_Access Transfer Policy Profile TypeATCF | EATF

The Access Transfer Control Function (ATCF) in the serving (visited if roaming) network provides the proxy role as well as B2BUA functionality (based on the call flow being processed) as defined in the IMS specifications. When SRVCC is enhanced with ATCF, the ATCF is included in the session control plane for the duration of the call before and after Access Transfer. The ATCF may be co-located with one of the existing functional entities within the serving network (i.e. P-CSCF or IBCF).

Emergency Access Transfer Function (EATF) provides IMS-based mechanisms for enabling service continuity of IMS emergency sessions. It is a function in the serving (visited if roaming) IMS network, providing the procedures for IMS emergency session anchoring and PS to CS Access Transfer. The EATF acts as a routing B2BUA which invokes third party call control (3pcc) to enable Access Transfer.

Refer to ATCF and EATF Support for details.





Feature Capability Indicator

Msc Assisted Mid CallDisable | Enable

Enable/Disable enumeration.

MSC Assisted Mid Call.

Ps Cs Alerting SRV CCDisable | Enable

Enable/Disable enumeration.

PS-CSAlertingSRVCC.

Cs Ps Alerting SRV CCDisable | Enable

Enable/Disable enumeration.

CS-PSAlertingSRVCC.

Cs Ps SRV CCDisable | Enable

Enable Disable enumeration.

CS-PSSRVCC.

Ps Cs Pre Alerting SRV CCDisable | Enable

Enable Disable enumeration.

PS-CSPreAlertingSRVCC.

Cs Ps Pre Alerting SRV CCDisable | Enable

Enable Disable enumeration.

CS-PSPreAlertingSRVCC.

Include ATCF_Include ATCFAlways | Criteria

When the option Always is selected, ATCF is included always without any criteria.

 

On the frame Copy Selected Atprofile, click Save to save the copied Atprofile. Click Undo Edits to undo all changes since the last saved configuration.

Note

If the field ID in the frame Copy Selected Atprofile is supplied with a value which is same as the ID of the Atprofile selected for copying, and values of any other field is modified, then the saved configuration results in the configuration of the Atprofile selected for copying getting changed itself, without creating any other distinct copy.

 

On saving the copied Atprofile successfully, the Success message appears.

Caption
0Figure
1Copy Success

Image Added

 

Delete an Atprofile

To delete an Atprofile from the list, select the Atprofile and click the X symbol to delete.

Caption
0Figure
1Delete Atprofile

Image Added

 

The pop-up Delete Atprofile appears, asking for confirmation of deleting the selected Atprofile. To delete, click Yes on the pop-up.

Caption
0Figure
1Delete Atprofile

Image Added

 

On successful deletion, the message Delete successful appears.

Caption
0Figure
1Successful deletion

Image Added

...

borderColorgreen
bgColortransparent
borderWidth2

Back to Table of Contents

Back to All