Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: added OID as a part of JIRA SBX-91903


Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.8.1.2.1.5.0.87

Description

This alarm indicates there is a connection issue with the remote server used for rsyslogthe SBC failed to establish a TCP connection with Rsyslog server.

RepetitionNone

Five minutes

Event Codes

sonusAlarmNodeID
sonusAlarmLevel
sonusAlarmSequenceId
sonusAlarmTime
sonusAlarmDescription
sonusServerIpAddress

Instance Fields

sonusServerIpAddress

Action

Check the rsyslog service status on the remote server and if the SBC can communicate to the remote server.

Impact

Event messages are not written to the remote server.

Clearing

Automatic; sonusCpSystemRsyslogRemoteServerConnectionRecovered

Pagebreak