Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.10.1.1.1.0.62

Description

This trap alarm is raised when the TCP connection to a particular monitoring server cannot be is not established after three failed attempts (IPv4).

Repetition

Yes

Event Codes

  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescriptin
  • sonusMonIpAddress
  • sonusMonPortNum

Instance Fields

  • sonusMonIpAddress
  • sonusMonPortNum

ActionThe state of

Re-establish the TCP connection.

Info
titleNote

Manually disable or enable the monitoring profile

must be disabled or enabled manually after corrective action

state after taking corrective actions.

Impact

The SBC cannot stream SIP PDU PDUs to monitor the monitoring server as because the TCP connection cannot be is not established.

Clearing

Manual

...