Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Noprint
Panel
borderColorgreen
bgColortransparent
borderWidth2

Back to Table of Contents

Back to Configuration

Back to Configuration - Profile Management

Back to Profile Management - Signaling Profiles

Back to Signaling Profiles - Signaling Profile

Back to Signaling Profile - Egress - Profile Management

Specifies the NFCI Default Use the NFCI Default Values window to specify default NFCI (National Forward Call Indicators) parameter values.

To View and Edit

...

NFCI Default Values

On the SBC main screen, go to Configuration > Profile Management > Category: Signaling Profiles > Signaling Profile > Egress >Uk Isup > Nfci Default Values.UK ISUP > NFCI Default Values or
All > Profiles > Signaling > Signaling Profile > Egress > UK ISUP > NFCI Default Values

Select the desired Signaling Profile you want to configure from the drop-down list to view its respective Nfci Default Values parameters. The Nfci NFCI Default Values window is displayed.

Caption
0Figure
1Signaling Profiles - Signaling Profile - Egrees - Nfci NFCI Default Values Window

Image Modified

The following fields are displayed:Use the following table to configure the option and then click Save.

Caption
0Table
1Signaling Profile - Egress - Nfci NFCI Default Values parametersParameters
ParameterDescription
Cli Blocking Available

When this option is enabled and interworking between a non-UK ISUP variant to and a UK ISUP- If selected, the CLI Blocking Available bit is set in the NFCI (National Forward Call Indicators) parameter of the outgoing UK ISUP IAM. For a UK ISUP to UK ISUP route? If selected, the CLI Blocking Available bit is set in the NFCI parameter of the outgoing UK ISUP IAM. The options are:

  • disable Disable (default)
  • enable

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.

  • Enable

Pagebreak