Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Noprint
Panel
borderColorgreen
bgColortransparent
borderWidth2

Back to Table of Contents

Back to All

Back to All - Address Context

Back to Address Context - Zone

Back to Zone - Sip Trunk Group

Back to Sip Trunk Group - Signaling (All)

Back to Sip Trunk Group - Signaling - Timers

This The Binary Floor Control Protocol (BFCP) timer object is used to define re-transmission timer parameters for a specified Sip Trunk Group.

To View and Edit Bfcp Timer

On the SBC main screen, navigate to to All >  > Address Context > Zone > Zone > Sip  SIP Trunk Group > Signaling > Timers >  > Signaling Timers > Bfcp Timer.

The Bfcp Timer can be checked for each Address Context, Zone, and Sip Trunk Group or for all the Address Contexts, Zones, and Sip Trunk Groups. Use the drop-down box to select the desired Address Context, Zone, and Sip Trunk Group.

...

Excerpt Include

Timers - Bfcp Timer

...

...

Image Removed

The Bfcp Timer window is displayed.

...

Timers - Bfcp Timer

...

Image Removed 

nopaneltrue

Pagebreak

The following fields are displayed:

Caption
0Table
1Bfcp Timers Parameters

Parameter

 Description

 Req Timer T1BFCP protocol request re-transmission timer T1 (in milliseconds). (range = 1-10000 / default = 500).
 Resp Timer T2BFCP protocol response re-transmission timer T2 (in milliseconds). For the configured time all subsequent duplicate requests will respond by replaying the cached response. (range = 1-65535 / default = 10000).

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.