Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Noprint
Panel
borderColorgreen
bgColortransparent
borderWidth2

Back to Table of Contents

Back to Monitoring

Back to Monitoring - System

Back to System - Hardware Status

This object specifies the SBC server Daughter Board (DB) module statusUse the Daughter Board Status window to view the status of SBC Daughter Board modules in SBC 5xxx and SBC 7000 systems.

Include Page
Not_for_SWe
Not_for_SWe

On SBC main the

Spacevars
0product
 main screen, go to Monitoring > System > Category: Hardware Status >Daughter Board Status. Status or
All > System > Daughter Board Status

The Daughter Board Status window is displayedopens.

Caption
0Figure
1Daughter Board Status
Image Modified 

By default only ten entries are displayed in a view. You can choose the number of entries to be displayed under the Show entries drop down box. 

The following fields are output is displayed:

Caption
0Table
1system daughterBoardStatus Daughter Board Status Parameters
NOTE: For 5x00 systems, only the “enabled” Enabled state displays in the results.

Parameter

Description

Server NameServer name.
Slot Specifies the slot associated with the DSP board.
Daughter Board IdID

Daughter board identifier.

Spacevars
0series
:

  • SPS100 – SBC 5x00 SPS100 module
  • DB0 – SBC 5x00 SPS100DB 0 module
  • DB1 – SBC 5x00 SPS100DB 1 module
  • DSP20 – SBC 5x10 DSP20 module
  • DSP25 – SBC 5x10 DSP25 module

Spacevars
0series2
:

  • FRU_DSP1 –  – SBC 7000 DSP-LC slot 1
  • FRU_DSP2 SBC 7000 DSP-LC slot 2

  • FRU_DSP3 SBC 7000 DSP-LC slot 3

  • FRU_DSP4 – SBC 7000 DSP-LC slot 4

PresentIndicates if the module is present (True or notFalse).
Product NameIdentifies manufacturer module name (if present).
Serial Num

Identifies the serial number of the module (if present).

note

The maintenance fields Image Load Failure Count and Fpga Version  do not apply to SPS100 cards.
 Part Num The part number of the module (if present).
 Operational Status Operational state of daughter board.
  • disabled Disabled – Card is disabled.
  • dryup Dryup – Card is enabled but in the process of drying up. Once completed, card will be set to ‘disabled’.
  • enabled Enabled – Card is enabled.
  • failed Failed – If a DSP2x or DSP-LC module fails to boot over three consecutive tries (typically due to a hardware failure), it is taken out of service and marked as state “failed”. The rest of the system continues to boot normally, including any other DSP modules. The module failure is logged/alarmed with trap “sonusConnexIpSystemCESlotFailedNotification”. The slot remains in the failed state until the module is disabled and re-enabled once a replacement card is installed.
  • loading Loading – Card is enabled but in the process of booting. Resources are not yet available. Once completed, card will be set to ‘enabled’.
  • locked Locked – Slot capacity is locked out due to mismatch (with “preserveRedundancy” “Preserve Redundancy” configured).

Note
 Image Load Failure Count  Number

Number of module boot failures since the last successful module boot, for use during diagnostic testing of a potentially failed module.

NOTE: This maintenance field does not apply to SPS100 cards.

Fpga Version Version 

 A card’s programmed firmware version (using the FPGA build date).

NOTE: This maintenance field does not apply to SPS100 cards.

 

Pagebreak