7.0 Licensing Common Note
7.0 Licensing Common Note
nopaneltrue

Panel

In this Section:

Table of Contents

 

Services enabled by a counted license can be configured with a Min Count and a Max Count value. When these values are equal, the 

Spacevars
0product
 requests and retains that number of licenses at the 
Spacevars
0product
 irrespective of demand for the license. When the values for these fields are different, the 
Spacevars
0product
 maintains the number of licenses configured in Min Count irrespective of demand, and it never requests more licenses than the configured Max Count value.

Info
titleNote

This configuration only applies if your SBC was configured in network license mode in a prior release. If you need assistance in setting your license mode, contact Ribbon Technical Support.

To view the list of configured required licenses, on the SBC main screen navigate to Administration > System Administration > License Management > Network License Settings > Required License. The Required License window is displayed.

Caption
0Figure
1Required License

Image Added

 

The Required License window consists of two tables:

  • License Info List - A table that displays detailed information on the network licenses used by the SBC. 

    Caption
    0Figure
    1Required License - License Info List (Network)

    Image Added

The parameters displayed in the License Info List window and their descriptions are given in the table below:

Caption
0Figure
1License Info List Parameter Descriptions
ParameterDescription
Feature NameThe name of a license feature.
License IDLicense ID.
Expiration DateLicense expiration date.
Usage LimitUsage limit for the licensed feature.
In UseThe number of instances of the license being currently used by the SBC.
 

  • Required License List - A table that displays information on the network licenses required for proper functioning of certain features of the SBC. For information on the parameters displayed in this table, see Required License - Field Description. Apart from viewing the required licenses, the Required License List table is equipped with options for editing and copying existing license parameters, as well as creating new required license parameters.

    Caption
    0Figure
    1Required License - Required License List

    Image Added

    To Create a Required License

    To create a new required license configuration:

    1. Click New Required License on the Required License List table. The Create New Required License window is displayed.

      Caption
      0Figure
      1Create New Required License

      Image Added

    2. Select a feature from the Feature Name list. Make necessary changes in the fields to configure the license requirements for the selected feature. For more information on the fields, see Required License - Field Description.

    3. Click Save to save the changes, or Cancel to cancel the changes.
    4. After successful creation, a confirmation message is displayed. Click OK to complete the process.

To Edit a Required License

To edit a required license configuration:

  1. Click the radio button adjacent to the license's name in the Required License List table. The Edit Selected Required License window is displayed.

  2. Make necessary changes in the fields. For more information on the fields, see Required License - Field Description.
  3. Click Save to save the changes, or Cancel to cancel the changes.
  4. After successful update, a confirmation message is displayed. Click OK to complete the process.

To Copy a Required License

To copy an existing required license configuration:

  1. Click the radio button adjacent to the license's name in the Required License List table.

  2. Click Copy Required License on the Required License List table. The Copy Selected Required License window is displayed.

  3. Make necessary changes in the fields. For more information on the fields, see Required License - Field Description.
  4. Click Save to save the changes, or Cancel to cancel the changes.
  5. After successful update, a confirmation message is displayed. Click OK to complete the process.

 

The fields displayed in the Edit, Copy and Create windows are are:

Anchor
Required License - Field Descriptions
Required License - Field Descriptions
Caption
0Table
1Required License - Field Descriptions
FieldDescription
Feature Name

The name of the feature for which a license is required. Select the feature's name from the drop-down list adjacent to the field. The drop-down list displays the following options:

  • SRTP
  • SBC-LI
  • ENCRYPT
  • SBC-RTU
  • DSP-EVRC
  • DSP-G722
  • POL-BASE
  • VDSP-RTU
  • DSP-AMRNB
  • DSP-AMRWB
  • SBC-SIP-I
  • SBC-VIDEO
  • SBC-4X1GMP
  • SBC-SIP323
  • SBC-SIPREC
  • SBC-1X10GMP
  • SBC-MRF-RTU
  • SBC-NICEREC
  • SBC-POL-RTU
  • SBC-PSX-RTU
  • SBC-POL-E911
  • SBC-POL-ENUM
  • SWE-INSTANCE
Min Count

Use this parameter to specify the minimum number (1–256000) of licenses the SBC will request from the SLS to retain at the SBC (regardless of demand) when the associated license is first configured. (Default = 1)

When the Min Count is set to the default value of "1", one license is requested from the SLS and retained at the SBC to verify the availability of the feature license. When Min Count is configured for a service that is already active, the SBC immediately requests the additional licenses required to reach the configured minimum count. If the licenses that are present at the SBC have already surpassed the configured minimum, the SBC does not make any additional license requests.

If a configured minimum count is not available at the SLS, the alarm sonusSbxMinimumLicenseCountThresholdNotReached is raised to indicate the SBC is running below the configured minimum count for the associated license.

Max Count

Use this parameter to specify the maximum number of licenses (2–1000000, or "unlimited") the SBC can request from the SLS. (Default = "unlimited")

If the system is utilizing licenses and the Max Count is reconfigured to a value less than the licenses already in use, the SBC does not reject existing sessions using the license, and throttles new attempts requiring the license to the newly configured limit. 

If the SBC is operating above the configured threshold, the alarm sonusSbxMaximumLicenseCountThresholdExceeded is raised. This condition restricts further use of the licensed feature until the number of licenses at the SBC drop below the configured maximum.

Info
titleNote

 Min Count and Max Count are not configurable for services controlled by instance licenses. These services are enabled system wide when a single token of the feature license is present at the system.

To Delete a Required License

To delete a required license:

  1. Click the radio button adjacent to the license's name in the Required License List table.

  2. Click the X (Delete icon) at the right end of the row containing the required license in the Required License List table.

  3. Confirm the deletion when prompted.

  4. After successful deletion, a confirmation message is displayed. Click OK to complete the process.

Noprint
Panel
borderColorblack
bgColororange
borderWidth3
borderStyledashed
titleRelevant ICD

Please Review wrt the ICD SBX-2879 and 28773 Integrate SBC with Network Licensing Infrastructure

Add_workflow_for_techpubs
AUTH1sbsarkar
REV5bscoggins
REV6bscoggins
REV3mcourtney
REV1sgibbard

 

 

Lorem Ipsum

 