Add_workflow_for_techpubs | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
This feature extends the number of T1/E1 spans supported by SBC 1000 from 2 to 4 spans with the addition of a second T1/E1 line card. Previously the SBC 1000 supported one 2-port T1/E1 line card with the first T1/E1 port being licensed by default and the second port controlled by a software license. In this release, the first port is licensed by default, and the next three ports are configurable through software licensing.
...
The additional 2-port T1/E1 line card (slot 8) is accessed through two ports (labeled 1 and 2) on the left side of the SBC 1000 Front Panel.
Note | ||||
---|---|---|---|---|
| ||||
The original 2-port T1/E1 line card (slot 7) is accessed through two ports on the right side of the SBC 1000 Rear Panel. |
Caption | ||||||
---|---|---|---|---|---|---|
| ||||||
|
The following diagram shows a typical network layout of the SBC 1000 to PSTN or PBX, or both in upstream or downstream layout using T1 or E1 cables.
Caption | ||||||
---|---|---|---|---|---|---|
| ||||||
...
The Inventory Report tab shows the new Telco Module 8 in the location column. Caption
0 | Figure |
---|---|
1 | Inventory Report |
3 | Inventory Report |
The SBC 1000 Overview tab (System > Overview) shows the status of the 2-port DS1 line card in the front slot (Module 8).
Caption | ||||||
---|---|---|---|---|---|---|
| ||||||
SBC 1000 Ports view (Settings > Node Interfaces > Ports) shows the new DS1 port 8:1 and 8:2 along with configured port type, port status and port counters. Caption
Although there are no new configurable items added to SBC 1000 as a result of this feature, the existing applicable configuration elements are extended to include Port Configuration for module 8.
The SBC 1000 Set DS1 Port Type window of the Web UI (Settings > Node Interfaces > Ports>) window is modified to include module 8 as shown below. This window is used to set the port type of module 8 to T1 or E1 for both ports. Caption
0 | Figure |
---|---|
1 | DS1 Port Type |
3 | DS1 Port Type |
The DS1 Relay Configuration object (Settings> Node Interfaces > Ports > Relay Config) allows the user to choose a relay configuration state on modules 7 and 8 of Online, Passthrough or Poweredown Passthrough. The SBC 1000 does not support choosing different settings between the two modules. Caption
To use the additional two DS1 ports on the new SBC 1000 chassis requires installation of the following::
Pagebreak |
---|