This article describes the steps necessary to configure the 

Spacevars
0product
so that a call may be placed from a SIP phone through the 
Spacevars
0product
to an ISDN endpoint as depicted by the following call flow:

Section
Column
width535px

Topology

Image Modified

Column

On this page:

Table of Contents

...

  1. In the WebUI, click the Settings tab.

  2. In the left navigation pane, go to Transformation

  3. Add a new Transformation Table.

  4. Add two entries to the new Transformation Table as show below.

    Image Removed

    configured as follows:

     

    Caption
    0Table
    1Transformation Table Configuration
    Input Field TypeInput field ValueOutput Field TypeOutput Field ValueMatch TypeDescription
    Called Address Number.*6(\d{3})$Called Address/Number6/1MandatoryLyncSetup: Full Number
    Calling Address Number(.*)Calling Address/Number\1MandatoryLyncSetup: Full Number

Call Routing Table Configuration

  1. In the WebUI, click the Settings tab.

  2. In the left navigation pane, go to Call Routing Table.

  3. Add a new Call Routing Table.

  4. Add an entry to the new Call Routing Table and configure it as shown below.

    Image Removed

    with the values below; keep the fields not listed as the default values.

     

    Caption
    0Table
    1Call Routing Table Configuration
    FieldValue
    Number/Name Translation Table Select appropriate Translation Table (i.e., Calls to ISDN phones)
    Destination Signaling GroupSelect appropriate Signaling Group (i.e., ISDN:Lync Setup)

SIP Signaling Group Configuration

  1. In the WebUI, click the Settings tab.

  2. In the left navigation pane, go to Signaling Groups.

  3. Add a new SIP Signaling Group and configure it as shown below.

    Image Removed

    with the values below; keep the fields not listed as the default values.

     

    Caption
    0Table
    1Call Routing Table Configuration
    FieldValue
    SIP ModeLocal Registrar
    RegistrarSIP Phones

ISDN Port Configuration

  1. In the WebUI, click the Settings tab.

  2. In the left navigation pane, go to Node Interfaces > Ports.

  3. Click the port you wish to configure.

  4. Configure the port as shown below.

    Image Removed

    with the values listed below; keep the keep the fields not listed as the default values.

     

    Caption
    0Table
    1Call Routing Table Configuration
    FieldValue
    Port AliasSpecifies an alias for the port (i.e., T1 to Meridian)
    DescriptionSpecifies the description  (i.e., T1 to Meridian)

ISDN Signaling Group Configuration

  1. In the WebUI, click the Settings tab.

  2. In the left navigation pane, go to Signaling Groups.

  3. Add a new ISDN Signaling Group.

  4. Configure the new ISDN Signaling Group as shown below.

    Image Removed

    with the values listed below; keep the fields not listed as the default values.

     

    Caption
    0Table
    1Call Routing Table Configuration
    FieldValue
    DescriptionDescription of Signaling Group
    Switch VariantQSIG
    Tone TableDefault Tone Table
    Call Routing TableSelect appropriate Call Routing Table

Verification

Endpoint Registration:

When the endpoint registers, the registration request arrives to the 

Spacevars
0product
through the SIP signaling group, the 
Spacevars
0product
responds to the REGISTRATION request with a 200 OK – a successful SIP endpoint registration occurs.

Using the Log Exchange utility, you can quickly verify the relevant SIP messaging:

Panel
borderStylenone

Caption
0Figure
1Verify SIP Messaging

Image Modified