Reliability data for the
...
SBC 1000 and SBC 2000 is provided below. Reliability data such as MTBF are non-binding estimates of product performance and is based on use of the products in compliance with related product data sheets, including, without limitation, within the specified electrical, thermal and mechanical parameters. An MTBF measurement is based on a statistical sample and is not intended to predict any one specific unit’s reliability; thus MTBF is not, and should not be construed as, a warranty measurement. Please consult your
...
Spacevars | ||
---|---|---|
|
Info |
---|
This report is also available in PDF format. (November 26, 2014) |
Predicted MTBF values were calculated according to Telcordia Technologies Special Report SR-332, Issue 1, May 2001 using Method II, (Black Box stress method integrated with laboratory data) including noted items below.
MTBF value for chassis fans relate to the failure rate of the fans during their useful life, which is 70,000 hours per fan.
Observed MTBF values are derived from actual field reliability measurements of SBC 1000 chassis, cards and other sub-assemblies as of November 2016. These values are subject to change as
...
Spacevars | ||
---|---|---|
|
Warning | ||||||||
---|---|---|---|---|---|---|---|---|
| ||||||||
This data is provided "as is" without any express or implied warranty of any kind including warranties of merchantability or fitness for any particular purpose. In no event shall
|
Info | ||||||||
---|---|---|---|---|---|---|---|---|
Values on this page apply to pre-6.1 hardware.
|
The tables below list the MTBF values for constituent (i.e. minimally configured base systems and optional daughter cards) used in the SBC 1000 and SBC 2000
...
. Fully assembled, customer orderable system-level SBC Edge product MTBF values can be determined from the equation documented in the next section.
...
Caption | ||||
---|---|---|---|---|
|
...
|
...
|
...
|
...
|
...
|
...
|
...
|
...
|
...
|
...
|
...
|
...
|
...
|
...
|
...
|
...
|
...
|
...
|
...
|
...
|
...
|
...
*Availability of SKUs subject to applicable end-of-product sale notices. Please refer to Ribbon Support Services. **Observed MTBF values derived from actual field reliability measurements of SBC 1000 base chassis equivalent to the SBC-1K-SIP-E, cards and other sub-assemblies (as opposed to customer-orderable, system-level SBC Edge product SKU) as of November 2016. MTBF data subject to change over time as additional measurements are received. Please contact your
|
Caption | |||||||||
---|---|---|---|---|---|---|---|---|---|
| |||||||||
|
...
Caption | ||||
---|---|---|---|---|
|
...
| |||
|
...
|
...
|
...
|
...
|
...
|
...
|
...
|
...
|
...
|
...
|
...
|
SBC Model | Description | MTBF in Years |
---|---|---|
SBC-2K-S-1 | Chassis + SBA + C900 DSP | 11.3 |
SBC-2K-2 | Chassis + 2x C900 DSP | 18.6 |
...
*Availability of SKUs subject to applicable end-of-product sale notices. Please refer to Ribbon Support Services. **Observed MTBF values derived from actual field reliability measurements of SBC 2000 base chassis, cards and other sub-assemblies (as opposed to customer-orderable, system-level SBC Edge product SKU) as of November 2016. MTBF data subject to change over time as additional measurements are received. Please contact your Ribbon sales representative for more information.
|
The following equation can be used to calculate the predicted and likely observed MTBF
...
values for a given SBC 1000 or SBC 2000 complete, fully assembled system. See Ribbon for a complete list of systems.
Code Block |
---|
Predicted or Observed MTBF of complete SBC Edge System = 1/ ((1/MTBF of Base System) + (1/MTBF of first desired constituent accessory) + (1/MTBF of second desired |
...
constituent accessory) ...) |
When using the equation, Ribbon customers must use only observed or predicted constituent values from tables 1 or 2 to determine the system-level SBC Edge product. By way of example: