MTBF (Mean Time Before Failure) Data

Reliability data for the

...

SBC 1000 and SBC 2000 is provided below. Reliability data such as MTBF are non-binding estimates of product performance and is based on use of the products in compliance with related product data sheets, including, without limitation, within the specified electrical, thermal and mechanical parameters. An MTBF measurement is based on a statistical sample and is not intended to predict any one specific unit’s reliability; thus MTBF is not, and should not be construed as, a warranty measurement. Please consult your

...

Spacevars
0company
sales contact should you have any questions or would like additional information.

Info

This report is also available in PDF format(November 26, 2014)

Predicted MTBF values were calculated according to Telcordia Technologies Special Report SR-332, Issue 1, May 2001 using Method II, (Black Box stress method integrated with laboratory data) including noted items below.

  • Integrated circuits and ferrite inductors use vendor provided laboratory data.
  • Purchased assemblies use reliability data provided by the OEM.
  • Environmental factor = Ground Benign
  • Quality Level 2 used for all components
  • Maximum operating temperature = 40°C
  • MTBF value for chassis fans relate to the failure rate of the fans during their useful life, which is 70,000 hours per fan.

Observed MTBF values are derived from actual field reliability measurements of SBC 1000 chassis, cards and other sub-assemblies as of November 2016. These values are subject to change as

...

Spacevars
0company
updates actual field reliability measurements on a periodic basis.

Warning
titleMTBF (Mean Time Before Failure) Considerations

This data is provided "as is" without any express or implied warranty of any kind including warranties of merchantability or fitness for any particular purpose. In no event shall

Spacevars
0company
. Networks or its suppliers be liable for any damages whatsoever (including, without limitation, damages for loss of profits, business interruption, loss of information) arising out of the use of, or inability to use, the data even if
Spacevars
0company
has been advised of the possibility of such damages.

Info

Values on this page apply to pre-6.1 hardware.

Spacevars
0company
will post 6.1 values in the near future, please contact your
Spacevars
0company
representative if you have any questions.


Base Predicted and Observed MTBF Values for Constituent SBC Edge Products

The tables below list the MTBF values for constituent (i.e. minimally configured base systems and optional daughter cards) used in the SBC 1000 and SBC 2000

...

. Fully assembled, customer orderable system-level SBC Edge product MTBF values can be determined from the equation documented in the next section.

 

...

Caption
0Table
1SBC 1000

...

Constituent MTBF Values
2center

...

SKU*DescriptionPredicted MTBF in Years

...

Observed** MTBF in Years
SBC-1K-SIP-

...

E Base System: Base Board, Fans & Power Supply

...

3.1

...

46.8
SBC-1K-CRD-DSP-MSBC C300 based DSP Card

...

239140
SBC-1K-CRD-2T1E1

...

SBC 1K Dual Port DS1 card

...

175421

...

SBC

...

-1K-CRD-4FXSLSBC 1K 4 port FXS Lower Card

...

161240

...

SBC

...

-1K-CRD-4FXSUSBC 1K 4 port FXS Upper Card

...

4031683

...

SBC

...

-1K-CRD-4FXOUSBC 1K 4 port FXO Upper Card

...

194240
SBC-1K-CRD-4BRI

...

SBC 1K 4 port BRI Card

...

162842

...

SBC

...

-1K-BRD-AME

Applications Solutions Module (AME unit), 4GB ECC MEMORY

75153

*Availability of SKUs subject to applicable end-of-product sale notices. Please refer to Ribbon Support Services 

**Observed MTBF values derived from actual field reliability measurements of SBC 1000 base chassis equivalent to the SBC-1K-SIP-E, cards and other sub-assemblies (as opposed to customer-orderable, system-level SBC Edge product SKU) as of November 2016. MTBF data subject to change over time as additional measurements are received. Please contact your

Spacevars
0company
sales representative for more information.

 

 

Caption
0Table
1SBC 1000 Model Configuration Examples
2center
SBC ModelDescriptionMTBF in Years
SBC 1K-4FXSBase + FXS Lower31.4
SBC 1K-FXSFXO-SBase + C300 DSP card + 2x FXS Lower + FXS Upper + FXO Upper + P4505 ASM13.0

...

Caption
0Table
1SBC 2000

...

Constituent MTBF Values
2center
SBC

...

SKU*DescriptionPredicted MTBF in YearsObserved** MTBF in Years
SBC-2K-

...

1Base System: Main Board, eUSB, Fans, Mid Plane, Single power supply

...

2.018.4
SBC-2K-CRD-DSP-H

...

SBC C900 DSP module196

...

188
SBC-2K-CRD-T1E1SBC Telco Module, 8 T1/E1 ports

...

122845
SBC-2K-CRD-24FXSSBC Telco Module, 24 FXS ports37

...

211
SBC-2K-BRD-SBA

...

SBC Application Solutions Module (SBA)79

...

80
SBC-2K-PSU-AC

...

AC Power Supply Module

...

11

 

 

SBC ModelDescriptionMTBF in Years
SBC-2K-S-1Chassis + SBA + C900 DSP11.3
SBC-2K-2 Chassis + 2x C900 DSP18.6

 

...

20

*Availability of SKUs subject to applicable end-of-product sale notices. Please refer to Ribbon Support Services.

**Observed MTBF values derived from actual field reliability measurements of SBC 2000 base chassis, cards and other sub-assemblies (as opposed to customer-orderable, system-level SBC Edge product SKU) as of November 2016. MTBF data subject to change over time as additional measurements are received. Please contact your Ribbon sales representative for more information.

 

Predicted and Observed MTBF Values for Customer-Orderable, System-Level SBC Edge Product

Method to Calculate Predicted and Observed MTBF Values

The following equation can be used to calculate the predicted and likely observed MTBF

...

values for a given SBC 1000 or SBC 2000 complete, fully assembled system. See Ribbon for a complete list of systems.

Code Block
Predicted or Observed MTBF of complete SBC Edge System = 1/ ((1/MTBF of Base System) + (1/MTBF of first desired constituent accessory) + (1/MTBF of second desired

...

 constituent accessory) ...)

 

When using the equation, Ribbon customers must use only observed or predicted constituent values from tables 1 or 2 to determine the system-level SBC Edge product. By way of example:

  • When seeking the predicted MTBF of an SBC 1000 complete, fully assembled system, only use the appropriate values from the Predicted MTBF in Years column of Table 1
  • When seeking the observed MTBF of an SBC 2000 complete, fully assembled system, only use the appropriate values from the Observed MTBF in Years column of Table 2

Examples of Calculated, Predicted, and Observed MTBF Values

The tables below shows examples of a Ribbon customer using the aforementioned equation to calculate the predicted and observed MTBF for example fully assembled, system-level SBC Edge products.

Caption
0Table
1SBC 1000 System-Level MTBF Examples
SBC SKU*DescriptionPredicted MTBF in YearsObserved MTBF in Years
SBC-1K-4FXSBase system + FXS lower card3.139.2
SBC-1K-FXSFXO-SBase system + C300 DSP card + 2x FXS Lower Card + FXS Upper Card + FXO Upper Card + AME unit2.820.8

 

*Availability of SKUs subject to applicable end-of-product sale notices. Please refer to Ribbon Support Services.



Caption
0Table
1SBC 2000 System Level MTBF Examples
2center
SBC SKU*DescriptionPredicted MTBF in YearsObserved MTBF in Years
SBC-2K-S-1Base system + SBA2.015.0

SBC-2K-6

Base system + 5x C900 DSP1.912.3

*Availability of SKUs subject to applicable end-of-product sale notices. Please refer to Ribbon Support Services.   