SBC SCOM Class | Error Criteria | Warning Criteria | Healthy Criteria | Notes |
---|---|---|---|---|
SBCSeries | Highest Alarm Severity is either Critical or Major. Where SLAs are present, these severities require immediate attention. | Highest Alarm Severity is Minor | Highest Alarm Severity is Warning or None | SBCSeries is an abstract class, these criteria apply to all inherited classes |
SBCLineCard | The card has configured ports and is either not present or is operationally down. | Not used | The card either has no configured ports, or is operationally up. | SBCLineCard is an abstract class representing pluggable cards (e.g.: SBC2000 DS1), these criteria apply to all inherited classes. When administrative state support is provided for cards the error criteria will include the card being administratively up. |
SBCModule | Not used | Not Used | This state always applies | SBCModule is an abstract class representing non-pluggable feature modules (e.g.: SBC1000 DS1). No service status information is supported for these modules. |
SBCPort | The port is administratively up and operationally down | Not used | The port is either administratively down, or operationally up. |
|
SBCDSPCard | The DSP card is out of service | Not used | The DSP card is in service | DSP Service Status is added via SNMP in the Flute release. |
SBCPowerSupply | The power supply is out of service | NOTE: Warning can be indicated based upon temp or voltage-out being out-of-spec. | The power supply is in service | Only applicable to SBC2000 with dual power supplies, otherwise the node will simply become SNMP-unreachable. |
SBCAdminPort | Not used | Not Used | Always | This is a recovery port , it is not mandatory to keep the cable plugged-in always in this port. Un-plugging the cable will make the port status down . This is a typical state in the customer location. So instead of showing the port down and alarming the operator , keep the port status healthy alway |
Action | Description | Interval |
---|---|---|
Object Discovery | Discovers
| Every 24 hrs Distributed [ 85500 – 86500 ] seconds |
Properties Polling | Properties for
| Every 6 hrs Distributed [ 21600 –22600] seconds |
Status Polling |
| Every 15 mins |
Within SCOM object classes represent entities whose health state is monitored by SCOM and presented to the user. SBC SCOM object classes are defined for persistent objects in the system.
...
Panel | ||
---|---|---|
| ||