The DC power supply is a Customer Replaceable Unit (CRU). The product code is SBC-5400-PSUDC.
Anchor DC Power Supply DC Power Supply
Caption | ||||
---|---|---|---|---|
| ||||
In a dual redundant power supply configuration, the Power Supplies are hot-swappable meaning that a power supply may be replaced without powering down the
Spacevars | ||
---|---|---|
|
Note | ||
---|---|---|
| ||
Before replacing a power supply in a redundant power supply configuration, verify the status of the redundant power supply. The “POK” LED status must be “solid green”. Removing the power supply when the redundant power supply does not show a solid green status, may cause the system to power down. Contact Sonus Customer Support if required. |
Caption | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||
|
Note |
---|
The chassis is shipped with one power supply, unless a second power supply is added at the time the order is placed. |
Note |
---|
To prevent damage from electrostatic discharge, an ESD strap is provided in the accessory kit. Refer to Connecting ESD Wrist Strap to install it. |
Perform the following procedure to replace a power supply:
Remove clear plastic protective cover on terminal strip.
Caption | ||||
---|---|---|---|---|
| ||||
Disconnect RTN and -48V connections by loosening two terminal strip screws using the #2 Philips screwdriver.
Caption | ||||
---|---|---|---|---|
| ||||
Spacevars | ||
---|---|---|
|
Tooltip | ||
---|---|---|
| ||
All
Spacevars | ||
---|---|---|
|
The storage environment for these CRUs is: