A unique signaling sequence in the format "ssp#", where # is an index value (ex. ssp1).
To View Ssp
On SBC main screen, go navigate to Configuration > Profile Management > Category: Service Profiles >Disconnect Signal Sequence Profile > Ssp.
...
Caption |
---|
0 | Figure |
---|
1 | Configuration - Profile Management - Disconnect Signal Sequence Profile - Ssp Main field |
---|
|
|
The Ssp window is displayed.
Caption |
---|
0 | Figure |
---|
1 | Profile Management - Service Profiles - Disconnect Signal Sequence Profile - Ssp |
---|
|
|
...
Caption |
---|
0 | Figure |
---|
1 | Profile Management - Service Profiles - Disconnect Signal Sequence Profile - Ssp Highlighted |
---|
|
|
The Edit Selected Ssp window is displayed below.
You would not be able to edit as the The field is read-only, and cannot be edited.
To Create Ssp
To create a new Ssp, click New Ssp tab on the Ssp List panel.
...
The following fields are displayed:
Include Page |
---|
| disconnectSignalingSequenceProfile_limitation |
---|
| disconnectSignalingSequenceProfile_limitation |
---|
|
Caption |
---|
0 | Table |
---|
1 | Disconnect SSP parameters |
---|
|
Parameter | Description |
---|
Name
| A unique signaling sequence in the format "ssp#", where # is an index value (ex. ssp1) | position | The position in Disconnect SSP at which to execute this step. This parameter allows you to insert steps into the middle of a Disconnect SSP without needing to renumber the index of the subsequent SSP steps. Positions begin with zero, so to insert a step in front of step 3 in the current Disconnect SSP, you declare a position of 2. (default = 0). | token | This parameter specifies the token, or action to perform. clear – Initiate call clearing procedures on the call. The disconnect reason is an integer specified in param1.delay – Delay further execution of the Disconnect SSP for the interval (in milliseconds) specified in param1.exec – Start execution of the SSP specified in param1.playAnn – Play the announcement specified in param1. The param1 value must match a previously established announcement number see "Announcement Package - CLI" .playTone – Play the tone specified in param1 for the duration specified in param2. The param1 value must match a defined tone type (see "Tone Profile - CLI" . If param2 is "0", the tone plays indefinitely (or until it completes on its own). Execution of the Disconnect SSP is suspended until the tone completes.
| param1
| A text field used to pass parameter #1 to the Disconnect SSP signaling sequence that is being configured. This parameter is dependent on the Disconnect signaling token used in this signaling sequence. | param2
| A text field used to pass parameter #2 to the Disconnect SSP signaling sequence that is being configured. This parameter is dependent on the Disconnect signaling token used in this signaling sequence. | state
| The administrative state of this Disconnect SSP. To reconfigure or delete the profile, set to 'disabled'. disabled (default) enabled
|
|
To Copy Ssp
To copy any of the created Ssp and to make any minor changes, click the radio button next to the specific Ssp to highlight the row.
...
Caption |
---|
0 | Figure |
---|
1 | Profile Management - Service Profiles - Disconnect Signal Sequence Profile - Ssp Fields |
---|
|
|
The Copy Selected Ssp window is displayed along with the field details which can be edited.
...
Caption |
---|
0 | Figure |
---|
1 | Profile Management - Service Profiles - Disconnect Signal Sequence Profile - Ssp Delete Confirmation |
---|
|
|
Click OK Yes to remove the specific Ssp from the list.
...