Attach the support brackets securely to the two rear posts of your equipment rack. Refer to the illustration below for visual details of the assembly:
|
Note |
---|
The illustration above shows the rear bracket assembly for a rack with a 30-inch depth. For racks with a 24-inch depth, do not use the 9-inch extension arm and attach each support bracket directly to the rear rack posts. |
...
Attach the 2 rack mounting ears securely to the front mounting posts of the equipment rack. Refer to the illustration below for visual details of the installation (click to enlarge).
|
Warning |
---|
Do not block the air vents on either side of the Sonus SBC 2000 chassis. Both sides of the unit must clear to ensure proper cooling of the unit. |
...
Attach the 2 rack mounting ears securely to the mounting posts of the equipment rack. Refer to the illustration below for visual details of the installation (click to enlarge).
|
...
Warning |
---|
You must power down the Sonus SBC 2000 system before installing or removing Interface Cards. Hot swapping of Interface Cards is not supported in Sonus SBC 2000 4.0.x. |
Wiki Markup |
---|
{multi-excerpt-include:pageTitle=Inserting and Removing Interface Cards|name=insert|nopanel=true} |
...
Place the cable management bracket on top of the pan handle plates.
Note |
---|
If you have installed the Sonus SBC 2000 chassis in a 2-post configuration, you must install the pan handle plates on the rear corners of the chassis. |
Use the provided cable ties to secure the cable management bracket to the pan handle plates. Refer to the illustration below for visual details of the installation (click to enlarge).
|
Warning |
---|
DO NOT INSTALL EITHER Sonus or TELECOM CABLES. You must complete the Initial Configuration before connecting the Sonus SBC 2000 system to your network. |
...