Page History
Add_workflow_for_techpubs | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
|
Use the following workflow to configure a pair of Edge 8300
Spacevars | ||
---|---|---|
|
The actions performed mirror those found in Running Setup Wizard - Standalone. Where there are differences, Attention boxes highlight instructions that are unique for High Availability. For example:
Info | ||||
---|---|---|---|---|
| ||||
For High Availability, set the 6WIND fastpath cores to 2. Decreasing the 6WIND cores to 2 allows you to increase the SBC SWe Edge CPUs to 4 later in this procedure. |
Use this workflow twice, once for each of the 8300 devices
Spacevars | ||
---|---|---|
|
Prerequisites
Login access to the
CLI as user system administrator (sysadm).Spacevars 0 product
Workflow
1 This procedure contains an Attention box highlighting actions unique for High Availability.
Multiexcerpt include | ||||
---|---|---|---|---|
|
Log In and Start the Setup Wizard
Multiexcerpt include | ||||
---|---|---|---|---|
|
Complete the System Menu
- From the System Startup Configuration window, select System and press Enter.
- The System Configuration window appears, showing available elements to configure:
Hostname, Time Zone, Time Server, RAMP Server, PRI type, and 6WIND fast path cores. - Press the down-arrow key to select an element in the System Configuration window.
For example,- Select Hostname and press Enter.
The Host Configuration window appears. - Configure the Hostname settings.
- Enter OK to save the settings.
The System Configuration window appears again, enabling you to select another element for configuration.
- Select Hostname and press Enter.
Configure the settings per the following Field Definitions.
Info icon false title ATTENTION For High Availability, set the 6WIND fastpath cores to 2. Decreasing the 6WIND cores to 2 allows you to increase the SBC SWe Edge CPUs to 4 later in this procedure.
- Enter OK to save the settings.
Multiexcerpt include MultiExcerptName System Configuration - Field Definitions PageWithExcerpt Running Setup Wizard - Standalone
Complete the BR1-5 Menus
From the System Startup Configuration window, select a bridge and press Enter.
The Bridge Configuration window appears, for example, BR1 Configuration window.Configure the BR settings per the following Field Definitions.
Info icon false title ATTENTION For High Availability, configure Bridge 5 (br5) as the HA interface:
- Disable DHCP Client (press the space bar to change the field to [ ]).
- Enter an IPv4 Address that is unique to the device being configured but on the same subnet as Bridge 5 on the other 8300 device.
- In the bridge Members field, enter the name of the port you used for HA cabling when you physically installed the device in Connect the Network Cables. Example: ge6.
Info title Note BR3 is an internal bridge with no provisionable fields for the members, DHCP server, and DHCP client fields.
Enter OK to save the settings.
Multiexcerpt include | ||||
---|---|---|---|---|
|
Complete the GE1-8 Menus
Multiexcerpt include | ||||
---|---|---|---|---|
|
Complete the SFP9-10 Menus
Multiexcerpt include | ||||
---|---|---|---|---|
|
Complete the Default Gateway Menu
Multiexcerpt include | ||||
---|---|---|---|---|
|
Complete the DNS Settings Menu
Multiexcerpt include | ||||
---|---|---|---|---|
|
Complete the SWe-Edge Settings Menu
- From the System Startup Configuration window, select SWe-Edge Settings and press Enter.
The Swe-Edge Configuration window appears. Configure the SWe Edge settings per . Refer to the following Field Definitions following this step for field descriptions, including default values.
Info icon false title ATTENTION For High Availability:
- Set the CPUs value to 4. This increases the CPUs assigned to SWe Edge processing, as required for High Availability processing. (Earlier, in Complete the System Setup, you decreased the number of CPUs assigned for 6WIND fastpath core CPUs to 2 to maintain the correct balance of CPU assignments.)
- Enter Bridge 5 (br5) for the value of Extra Interface 2. This is the interface you configured in Complete the BR1-4 Menus for the HA interface between the two 8300 devices.
- Enter OK to save the settings.
Multiexcerpt include | ||||
---|---|---|---|---|
|
Exit the Setup Wizard
Exiting the Setup Wizard saves the configuration settings and applies the changes. This will cause a service interruption for approximately 3 minutes. The system will be unreachable during this time.
Multiexcerpt include | ||||
---|---|---|---|---|
|