This Use this object specifies the packet outage to specify the Packet Outage detection parameters for this Gw GW Trunk Group.
On the SBC main screen, navigate to All > Address Context > Zone > Gw GW Trunk Group > Packet Outage.
The Packet Outage can be checked for each Address Context, Zone , and Gw GW Trunk Group or for all the Address Contexts, Zones, and Gw GW Trunk Groups created. Use the drop-down box to select the desired Address Context, Zone, and Gw GW Trunk Group.
The Packet Outage window is displayed.Figure 1: All - Address Context - Zone - Gw Trunk Group - Packet Outage
The following fields are displayed:
Table 1: Packet Outage parametersParameters
Parameter | Length/Range | Description |
---|---|---|
Minimum Duration |
0-65535 | The minimum outage (in milliseconds) on a call for that call to be counted as part of the packet outage detection algorithm. The |
default value is 6000. |
Minimum Calls |
0-65535 | The number of calls with outages required within the current interval to declare a packet outage event. The |
default value is 1000. |
Bandwidth Limit Reduction |
1-100 | The amount to reduce the bandwidth limit (as a percentage of the configured limit) when a packet outage is detected. The |
default value is 50. |
Detection State |
N/A | This flag enables automatic bandwidth reduction when a packet outage is detected. |
disabled
|
enabled
|
Detection Interval |
5-1440 | The size of the packet outage detection interval in minutes. The |
default value is 15. |
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.