In this section:
|
...
Info | ||
---|---|---|
| ||
The screen captures or code blocks on this page are examples only and are the same between releases, with the exception of the software version numbers. |
...
Note | ||||
---|---|---|---|---|
| ||||
It is recommended that you use the Rollback option with caution. To minimize the risk of a full
Before you execute this action, consult with Customer Support to determine if the rollback is required. Customer Support can assess whether a manual intervention could complete the upgrade and, therefore, the rollback outage can be avoided. |
Note | ||
---|---|---|
| ||
Do Do not log onto the system using the shared IP addresses on the Management CPUs during the rollback process described in this section. These addresses are disabled as part of the rollback process. |
...
Info | ||
---|---|---|
| ||
To rollback the IO back cards, use the same procedure required to upgrade the IO cards. |
To revert to a previous software version
Noprint | |
---|---|
|
...
Revert to Previous Software Version
Start
- Log onto the
Spacevars 0 series5
...
- Management CPU card in slot 14 or slot 24.
- Enter startmenu and press ENTER.
- Select System and press ENTER.
- Select Software Revisions and press ENTER.
Select Rollback and press ENTER.
Code Block title Example :::::::::::::::::::::::::::::::: Ribbon DSC :::::::::::::::::::::::::::::::: Rollback from Upgrade Utility _____________________________________________ Type "q" to quit from most prompts or CTRL-C. Getting software versions [ ==================== ] 100% This machine has identity 14. Reference current (new) version is: stp_sp2k_21_0_3_nb20230118 (Ribbon Linux release SP2000 7.4.6) Reference previous (old) version is: stp_sp2k_19_0_0_nb20191210 (SP2000 Linux release 7.4.18) Software Versions ID | OS | SW | Status ------------------------------------------------- 24 | 7.4.6 | stp_sp2k_21_0_3_nb20230118 | * 14 | 7.4.6 | stp_sp2k_21_0_3_nb20230118 | * Rollback in-container! Rollback targets: [24, 14] Type "yes" to proceed (yes/no):
If any cards are unreachable (for example, an IO slot that may not have been configured yet), a warning message is displayed.
Code Block Warning: some machines could not be properly contacted. Type "skip" to skip those CPUs [] or "yes" to proceed anyways. Anything else will abort the rollback process.:
Perform one of the following options:
- Enter skip to ignore the CPUs inside the square brackets [ ] and continue with the rollback. If none of the unreachable cards are CPUs, the list will be empty. It is recommended to skip those cards.
Enter yes to continue the rollback process as if all the CPUs are reachable.
...
...
Tip Entering anything else besides skip or yes will exit you from the rollback procedure.
The rollback procedure displays which CPU(s) will be rolled back. In this example, only one CPU needs to be rolled back because the other CPU is already in the previous load.
Code Block title Example Rollback in-container! Rollback targets: [14] Type "yes" to proceed (yes/no):
Enter yes to start the next rollback procedure.
...
If there are multiple CPUs, the remote CPU will be rolled back first. After the remote CPU is finished, you will be prompted to start the rollback for the local CPU.
...
Code Block title Example Ready for next rollback. Type "yes" to proceed
...
.
- Once all required rollbacks are completed, log onto the system and make sure that the rollbacks were successful (see Verify Rollback Properly Installed).
Rollback IOs to Previous Software Version
- Log onto the SP2000 Management CPU card in slot 14 or slot 24.
- Enter startmenu and press ENTER.
- Select System and press ENTER.
Select Software Revisions and press ENTER.
Select IO Versions and press ENTER.
Code Block title Example Do you have a new or replacement SP2K IO card to setup? (y/n): n AVAILABLE SOFTWARE VERSIONS -------------------------------------------------------------------------------- IO (current) AMC308 stp_sp2k_21_0_3_nb20230118 OS: rel_12_00_p07.sp2k.img (Servicepack) [none applied] IO (prev) AMC308 stp_sp2k_19_0_0_nb20191210 OS: rel_12_00_p07.sp2k.img (Servicepack) Not_Available RUNNING SOFTWARE VERSIONS (*=update required, ?=update unknown) CARD BUILD SERVICE O/S -SLOT----TYPE----------RELEASE-VERSION------PACK-----IMAGE------- -------------------------------------------------------------------------------- Slot 12 IO AMC308 * 19.0.0 (nb20191210) SP: OS: rel_12_00_p07.sp2k.img (p=servicepack is partially applied) Select IO slot number (12) to begin upgrade or decommissioning of individual card(s).
Enter the slot number.
Code Block title
Pagebreak |
---|
...
Noprint | |
---|---|
|
Example Enter slot # or ENTER to cancel: 12 Note: flex_slot.conf file doesn't exist ... This is ok if the SDA is not configured on the system. Software Update for IO Card in Slot #12 Determining running and current software version. Please wait... Running on IO (slot12_0): -Load: stp_sp2k_19_0_0_nb20191210 -OS: rel_12_00_p07.sp2k.img Current IO version (on MGMT CPU): -Load: stp_sp2k_21_0_3_nb20230118 -OS: rel_12_00_p07.sp2k.img -Servicepack: [none applied] 'u' - Update version (update slot12_0 to match the current load): -Load: stp_sp2k_21_0_3_nb20230118 -OS: rel_12_00_p07.sp2k.img 'd' - Decommission this IO card to prepare it for removal. Select action to take, or any other key to cancel: u
Enter U to update.
Code Block title Example Running IO software is out-of-date! You have opted to update/reboot slot #12, thereby loading the current software: -Load: stp_sp2k_21_0_3_nb20230118 -OS: rel_12_00_p07.sp2k.img -Servicepack: [none applied] Pushing image to the IO card in slot #12 Executing verify_io_image.sh script on IO board in slot #12 DO NOT INTERRUPT!! THIS MAY TAKE A FEW MINUTES... Done: IO board was already up-to-date Ensuring internal0 (DHCP) settings in /etc/pticonfig on IO card in slot #12. internal0 (DHCP) already disabled in /etc/pticonfig on IO card in slot #12. Ensuring internal0 LAG monitoring settings in /etc/pticonfig on IO card in slot #12. Ensuring internal1 network value in /etc/pticonfig on IO card in slot #12. Chassis Type value on IO: [ CHASSIS_TYPE=3U ] Enter 'y' to continue:
Enter Y to continue.
Code Block title Example Saving config to /dev/config0 Size of /dev/config0 is 4096 Kbytes The config file is 15364 bytes Erasing ..Max Erase Time: 648 mSecs Save succeeded Saving config to /dev/config1 Size of /dev/config1 is 4096 Kbytes The config file is 15364 bytes Erasing ..Max Erase Time: 692 mSecs Save succeeded Set IO card in slot #12 /etc/pticonfig internal0 tags to: DEVICES="internal0 internal1" # Options for internal0 (bond0) internal0_IPADDR="10.91.12.238" internal0_GATEWAY="" internal0_NETMASK="255.255.255.0" internal0_NETWORK="10.91.12.0" internal0_BROADCAST="10.91.12.255" internal0_USE_DHCP="N" internal0_DHCP_SETHOSTNAME="N" internal0_DHCP_SETDOMAINNAME="N" internal0_DHCP_HOST="" internal0_DHCP_CLIENTID="" internal0_DHCP_TIMEOUT="" internal0_DHCP_PORTS="" internal0_DHCP_OPTIONS="-d -R -G -N -I ''" internal0_ENET_CFG="" internal0_LAG_MON_IP1="10.91.12.2" internal0_LAG_MON_IP2="10.91.12.3" internal0_LAG_INTERVAL="200" internal0_TIPC_TOLERANCE="910" Rebooting IO card in slot #12. Press <return> to continue.
- Press Enter to continue.
Verify Rollback Properly Installed
Anchor | ||||
---|---|---|---|---|
|
Note | ||
---|---|---|
| ||
| ||
If an asterisk appears beside any of the system cards during the verification process, the rollback for the respective card was unsuccessful. In this case, it is recommended that you contact Customer Support. |
Start
- At the Linux prompt, enter startmenu, and press ENTER.
- Select System and press ENTER.
- Verify that the software has been rolled back properly by doing the following:
...
- navigate to the Software Revisions screen.
...
Select the required card (in this procedure CPU Versions), and pressing ENTER.
Make sure that the SS7 software and Linux software has been rolled back, all cards are running the same software, and that there is no asterisk beside any of the cards.
...
Tip The output of the “CPU Versions” command shows that the CPU card has “UPGRADED” status if this is the first time the command is issued after an upgrade. All subsequent “CPU Versions” commands show the number of processes running on each CPU.
Code Block title Example AVAILABLE SOFTWARE VERSIONS -------------------------------------------------------------------------------- No new load detected on system. Upload stp file before attempting upgrade. CPU (current) stp_sp2k_21_0_3_nb20230118 OS: 7.4.6 (Servicepack) [none applied] CPU (previous) Not_Available OS: N/A (Servicepack) RUNNING SOFTWARE VERSIONS (*=update required, ?=update unknown) CARD BUILD SERVICE O/S -SLOT----TYPE----------RELEASE--VERSION----PACK---IMAGE-------CARD STATUS--- -------------------------------------------------------------------------------- Slot 14 MGMT/ROUTING 21.0.3 (nb20230118) SP: 7.4.6 16 procs running Slot 24 MGMT/ROUTING 21.0.3 (nb20230118) SP: 7.4.6 16 procs running (p=servicepack is partially applied) Press <return> to continue.
- Press ENTER to cancel.
- To confirm that the IO cards are also running the same SS7 software and Linux software as the CPU cards, select IO versions and press ENTER.
Type n and press ENTER at the prompt "Do you have a new or replacement
IO card to set up? (y/n):"Spacevars 0 series5 Code Block title Example Do you have a new or replacement SP2K IO card to setup? (y/n): n AVAILABLE SOFTWARE VERSIONS -------------------------------------------------------------------------------- IO (current) AMC308 stp_sp2k_21_0_3_nb20210118 OS: rel_12_00_p07.sp2k.img (Servicepack) [none applied] RUNNING SOFTWARE VERSIONS (*=update required, ?=update unknown) CARD BUILD SERVICE O/S -SLOT----TYPE----------RELEASE-VERSION------PACK-----IMAGE------- -------------------------------------------------------------------------------- Slot 12 IO AMC308 21.0.3(nb20210118) SP: OS: rel_12_00_p07.sp2k.img Slot 22 IO AMC308 21.0.3(nb20210118) SP: OS: rel_12_00_p07.sp2k.img (p=servicepack is partially applied) Select IO slot number (12 22) to begin upgrade or decommissioning of individual card(s). Enter slot # or ENTER to cancel: No selection, exiting. Press <return> to continue.
- Press ENTER to cancel.
...