Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

To View and Edit CAC - Egress

On the SBC main screen, go to Configuration > System Provisioning > Category: Trunk Provisioning > Trunk Group > H323Trunk Group > CAC > Egress. The Egress window is displayed.

The CAC - Egress can be checked for each Address Context, for each Zone, for each H323Trunk Group created or for all the Address Contexts, Zones and H323Trunk Groups created. Use the drop-down list to select the desired Address Context, Zone and H323Trunk Group.


Figure 1: H323Trunk H323Trunk Group - CAC - Egress Main Fields

...

The Edit Egress window is displayed.

Figure 2: H323Trunk H323Trunk Group - CAC - Egress Edit Window

The following fields are displayed:


Table 1: H323Trunk Group - CAC - Egress ParametersParameter Descriptions:

Parameter

Description

Call LimitSpecifies the total number of calls allowed for Egress.
Call Rate MaxSpecifies the value of the maximum allowed burst in calls/second (above the allowed sustained rate) for egress call attempts. The default value is unlimited (range: 1-450, or unlimited. SBC 7000 range is 1-1350, or unlimited).
Call Burst MaxSpecifies the value of the maximum allowed burst (above the allowed sustained rate) for egress call attempts in calls/second.  The The default value is unlimited (range: 1-900, or unlimited. SBC 7000 range is 1-2700, or unlimited).

...

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.