maxLevel2

Specifies the details about the Options policer.

To View and Edit Options

On SBC main screen, go to Configuration > System Provisioning > Security Configuration >Sip Cac Profile > Options.

Select the desired Sip Cac Profile from the drop-down list to view its respective Options parameters.

The Options window is displayed.

Figure 1: Security Configuration - Sip Cac Profile - Options

The following fields are displayed:

Table 1: Options Parameters

Parameter

Description

Ingress Aggregate Preference

Specifies the preference for OPTIONS within the ingress aggregate policer. The value range from 1 - 10. The default value is 1.

Ingress Burst Size

Specifies the maximum burst size for ingress OPTIONS. The value range from 1 - 10000. The default value is 1.

Ingress Rate

Specifies the maximum ingress OPTIONS rate in OPTIONS per period. The value range from 1 - 1000 or unlimited.

Ingress Rate Period

Specifies the time period (in seconds) over which ingress OPTIONS rate applies. The value range from 1 - 10 seconds. The default value is 1 second.

Egress Aggregate Preference

Specifies the preference for OPTIONS within the egress aggregate policer. The value range from 1 - 10. The default value is 1.

Egress Burst Size

Specifies the maximum burst size for egress OPTIONS. The value range from 1 - 1000. The default value is 1.

Egress Rate

Specifies the maximum egress OPTIONS rate in aggregate messages per period. The value range from 1 - 1000 or unlimited.

Egress Rate Period

Specifies the time period (in seconds) over which egress OPTIONS rate applies. The value range from 1 - 10 seconds. The default value is 1 second.


Make the required changes and click Save at the right hand bottom of the panel to save the changes made.