Page History
...
Panel | ||||
---|---|---|---|---|
In this section:
|
Note | ||||||||
---|---|---|---|---|---|---|---|---|
Not applicable to |
Feature Overview
...
- In the WebUI, click the Tasks tab.
- In the left navigation panel, go to SBC Easy Setup > Easy Config Wizard.
From the Application drop down list, select ISDN PSTN
Configure per the field definitions below and click Next.
Configure Scenario Parameters - Field DefinitionsField Description Application Configuration template used: ISDN PSTN. Scenario Description Name to describe the setup. Telephone Country Country in which the ISDN PTSN endpoint is setup. Provider Type Hardcoded to ISDN.
Step 2: Configure ISDN PSTN for Endpoint
...
Configure ISDN PSTN Parameters
Field | Description |
---|---|
Port Type | Specifies the physical T1/E1 port used for this Signaling Group. Valid option: T1 or E1. |
DS1 Ports | The physical T1/E1 port number to which the PSTN line is physically connected. DS1 entries are configured with the following command buttons: Up (move a DS1 port up in the list), Down (move a DS1 port down in the list), Add (adds a DS1 port), and Remove (deletes a DS1 port). For example, click Add. Select the desired PSTN port and OK. |
Switch Variant | Specifies the ISDN variant for the port type in the ISDN Signaling Group. For T1
For E1:
|
ISDN Number Translation | Determines if the SBC should translate dialed PSTN digits as phone extensions. Valid options: Translation Extension (translates digits into phone extensions) or Passthrough Untranslated (does not translate digits). |
PBX Prefix | Numbers to prefix for the translated phone extension. This field is available only when ISDN Number Translation is set to Translation Extension. |
Extension Length | The number of digits used to account for the PSTN extension. Valid options: 2, 3, 4, or 5.This field is available only when ISDN Number Translation is set to Translation Extension. |
Clock Source | Specifies the source of the systems transmit clock.
|
Primary Clock Port | Specifies the primary port for the clock source. This field displays only when Network is selected as the Clock Source. |
Secondary Clock Port | Specifies the secondary port for the clock source. This field displays only when Network is selected as the Clock Source. |
ISDN Side | Specifies the ISDN user/network side for this signaling group to be created by this wizard. Valid entries: Network or User. |
Step 3: Summary
Easy Configuration Step 3 includes a summary of the information configured in Step 1 and Step 2.
...