Excerpt |
---|
Specifies the attributes for Composite tone configuration. On SBC main screen, go to All > Profiles Management > Media > Tone Profile >Composite Tone. Select the desired Tone Profile from the drop-down list to view its respective Composite Tone parameters. The Composite Tone window is displayed. |
Figure 1: Profile Management - Media Profiles - Packet Service Profile - Tone Profile - Composite Tone
Image Removed
The following fields are displayed:
...
Image Added
|
...
Tone1 Frequency | Specifies Tone 1 Frequency in Hertz. If 0, then silence is generated. Only valid if generation method is singleTone, dualTone, or compositeTone. |
|
...
Tone1 Power | Specifies Tone 1 Power in dBm. Power levels range from -50 dBm (minimum power) to +3 dBm (maximum power). Only valid if generation method is singleTone, dualTone, or compositeTone. |
|
...
Tone1 Apply Cadence | Specifies the cadences to which Tone 1 is applied. Application is as follows: If 0, then Tone 1 is applied to Cadences 1, 2, and 3. If 1, then Tone 1 is applied to Cadence 1. If 2, then Tone 1 is applied to Cadence 2. If 3, then Tone 1 is applied to Cadence 3. Only valid if generation method is compositeTone. |
|
...
Tone2 Frequency | Specifies Tone 2 Frequency in Hertz. If 0, then a single frequency tone is generated. Only valid if generation method is dualTone or compositeTone. |
|
...
Tone2 Power | Specifies Tone 2 Power in dBm. Power levels range from -50 dBm (minimum power) to +3 dBm (maximum power). Only valid if generation method is dualTone or compositeTone. |
|
...
Tone2 Apply Cadence | Specifies the cadences to which Tone 2 is applied. Application is as follows: If 0, then Tone 2 is applied to Cadences 1, 2, and 3. If 1, then Tone 2 is applied to Cadence 1. If 2, then Tone 2 is applied to Cadence 2. If 3, then Tone 2 is applied to Cadence 3. Only valid if generation method is compositeTone. |
|
...
Tone3 Frequency | Specifies Tone 3 Frequency in Hertz. If 0, then a single or dual frequency tone is generated. Only valid if generation method is compositeTone. |
|
...
Tone3 Power | Specifies Tone 3 Power in dBm. Power levels range from -50 dBm (minimum power) to +3 dBm (maximum power). Only valid if generation method is compositeTone. |
|
...
Tone3 Apply Cadence | Specifies the cadences to which Tone 3 is applied. Application is as follows: If 0, then Tone 3 is applied to Cadences 1, 2, and 3. If 1, then Tone 3 is applied to Cadence 1. If 2, then Tone 3 is applied to Cadence 2. If 3, then Tone 3 is applied to Cadence 3. Only valid if generation method is compositeTone. |
|
...
Tone4 Frequency | Specifies Tone 4 Frequency in Hertz. If 0, then a single or dual frequency tone is generated. Only valid if generation method is compositeTone. |
|
...
Tone4 Power | Specifies Tone 4 Power in dBm. Power levels range from -50 dBm (minimum power) to +3 dBm (maximum power). Only valid if generation method is compositeTone. |
|
...
Tone4 Apply Cadence | Specifies the cadences to which Tone 1 is applied. Application is as follows: If 0, then Tone 4 is applied to Cadences 1, 2, and 3. If 1, then Tone 4 is applied to Cadence 1. If 2, then Tone 4 is applied to Cadence 2. If 3, then Tone 4 is applied to Cadence 3. Only valid if generation method is compositeTone. | Decay Time Constant | Specifies exponential decay time constant in milliseconds. If 0, then no decay is applied. Maximum value is 2000 msec. Only valid if generation method is compositeTone. | Decay Frequency Delta | Specifies rate of change (Hz/s) of the tone frequency. If 0, then no frequency change rate is applied. Only valid if generation method is compositeTone. | Decay Apply Tone Bit Map | Specifies the tones to which decay and frequency rate change are applied. Application is by bitmap: - If 0, then decay/frequency rate change is not applied to any tone. If 1, then decay/frequency rate change is applied to tone 1.
- If 2, then decay/frequency rate change is applied to tone 2.
- If 3, then decay/frequency rate change is applied to tones 1 and 2.
- If 4, then decay/frequency rate change is applied to tones 3 and so on.. If 15, then decay/frequency rate change is applied to tones 1, 2, and 3. Only valid if generation method is compositeTone.
|
Make the required changes and click Save at the right hand bottom of the panel to save the changes made. |