Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Multiexcerpt
MultiExcerptNameExecute Initial Config Procedure
Start
  1. From the Main Menu, select Set Initial Configuration, and press ENTER.



  2. Enter y, and press ENTER.  
    1. If your system is not licensed for PCE, the system automatically executes the initial configuration procedure. Go to step 5.
    2. If it is detected that PCE has been licensed on this system, the following screen is displayed. Go to step 3.


  3. If your system is licensed for PCE, do one of the following:
    1. Only one DSC system is running PCE.

      1. Select 3 - Not as a Mated Pair. Go to step 4.
         

    2. Two DSC systems are running PCE.

      1. Enter 1 - Mated Pair as Node 1, and press ENTER. 
        You are prompted to enter the IP addresses for the Routing CPU cards.

      2. Enter the required IP Addresses for Node 2 as you configured this address in To configure the Routing IP traffic interfaces if PCE is licensed on a mated pair system
        After entering each IP address, go to step 4. 
         

  4. Press ENTER.
    The system automatically executes the initial configuration procedure.

    Tip
    titleTip

    After the system executes the initial configuration for Node 1, you must execute this procedure for Node 2 in the mated pair configuration. Make sure to select  2 - Mated Pair as Node 2 and enter the IP addresses you configured for Node 1.

    You are prompted to decide whether EMS access should be enabled on the system that you are configuring.

    Tip
    titleTip

    For detailed information about EMS access, refer to Element Management System.


  5. Do one of the following.

    1. If you want to have EMS access enabled, press y, and press ENTER, and go to step c.
    2. If you do not want EMS access enabled, go to step d.
    3. If you pressed y and and ENTER in step a, the system enables EMS access and executes the initial configuration procedure, and restarts the Web UI.


    4. If you do not want to enable EMS access, enter n, and press ENTER.
      A message appears informing you that EMS access was not enabled (EMS snmp rw community string was not activated), and the system continues to automatically execute the initial configuration procedure and restart the Web UI.   

    Tip
    titleTip

    If, at a later time, you want to enable EMS access, refer to Enabling EMS


    Tip
    titleTip

    You have to wait approximately five minutes before you can access the Main Menu in Web UI after the system completes the execution of the initial configuration procedure.


...