The SBC, which continuously captures encrypted signaling packets of SIP over TLS at layer 2, has been enhanced to to capture decrypted signaling packets as well.

The SIP PDUs (Protocol Data Units) are captured at the application layer and continuously streamed to the monitoring server. Configurable Headers are included in SIP PDUs to enable the monitoring server to decode SIP signaling properly. Headers have source and destination IP address/Port information along with additional information which is configurable – this information is needed by the monitoring server in order to correlate the stream received.

The packet is captured at ingress leg without SMM applied and with SMM applied on egress leg, which is essentially what is being sent on the wire.  To lessen performance impact, all socket-management activities to the monitoring server use a separate SIPSM (SIP Signaling Monitor ) process receives all signaling packets from the SIP Signaling Gateway (SIPSG) and streams to the configurable external monitoring server either over UDP or TCP.

A profile attached to the signaling port is a trigger for this feature. All feature-related configuration can be set in this profile.

Terminology

The following terminology and acronyms are used in this documentation:

TLSTransport Layer Security
 SIPSession Initiation Protocol
 UNIUser Network Interface 
 NNINetwork-Network Interface 
 TCPTransmission Control Protocol


Command Syntax

The command syntax to configure a Monitoring Profile is shown here:

Code Block
languagenone
%set profiles services monitoringProfile <monitoring profile name> 
    additionalInformation <string>
    filter <transport | trunkgroup>
    headerPresence <disabled | enabled>
    mgmtInterfaceGroup <ip | mgmtGroup>
    monitoringIpAddress (IP address>
    monitoringIpPort <int | 0 .. 65535>
    signalingPackets <all | none | tls>
    state <disabled | enabled>
    transport <tcp | udp>
    type <IP | mgmt>


Command Parameters


Caption
0Table
1Command Parameters for monitoringProfile


ParameterLength/RangeDescriptionM/O
additionalInformationstring: 256 characters

Additional information in the header to send towards the monitoring server.

This parameter is available when headerPresence is "enabled".

O

filter

N/A

This table contains filters for the profile. The filter parameter is displayed only when signalingPackets is set to "none".

  • transport – Transport type used to filter the packets.
  • trunkgroup – IP TG filter used to filter the packets.
O

headerPresence

N/A

Specifies if X header presence towards monitoring server is enabled or not.

  • disabled
  • enabled
O

mgmtInterfaceGroup

N/A

The Management Interface Group to use for communicating with monitoring server.

  • mgmtGroup (default)
O

monitoringIpAddress

<IP address format>

IP address of the monitoring server.

M

monitoringIpPort

0-65535

TCP/UDP port for the monitoring server.

M
monitoringProfile1-23 charactersThe name of the Monitoring Profile.M

signalingPackets

N/A

Specifies if all signaling packets, or only decrypted TLS packets, are sent towards monitoring server from all TGs.

O

state

N/A

Administrative state of this Monitoring Profile.

  • disabled
  • enabled

transport

N/A

Choose the transport protocol to use for sending packets to the monitoring server.

  • tcp – Transmission Control Protocol
  • udp – (default) User Datagram Protocol
O

type

N/A

Interface type supported by monitoring server. 

  • ip – When selected, two fields are supported: addressContext and ipInterfaceGroup.
  • mgmt – (default) When selected, mgmtInterfaceGroup is supported.
O


 


The command syntax to set a Monitoring Profile Name per SigPort is shown here:

Code Block
titleExample
% set addressContext <address_context> zone <zone_name> sipSigPort 1 monitoringProfileName <monitoring_profile_name>

In general, you can configure monitoringProfile as shown below:

Code Block
% set profiles services monitoringProfile test_monitoring_profile monitoringIpAddress 10.54.21.25 monitoringIpPort 80 headerPresence enabled header 1 headerName To sourceIpPort enabled destinationIpPort enabled additionalInformation enabled date enabled timestamp enabled vlanTag enabled


Command Parameters


Caption
0Table
1Command Parameters for monitoringProfile


ParameterLength/RangeDefaultDescriptionM/O
monitoringProfileName24
Name of Monitoring Profile used for this SIP Signaling Port.O



Pagebreak