Page History
Add_workflow_for_techpubs | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Panel | ||||
---|---|---|---|---|
In this section:
|
This section describes
Spacevars | ||
---|---|---|
|
To install and configure
Spacevars | ||
---|---|---|
|
Warning | ||||||||
---|---|---|---|---|---|---|---|---|
| ||||||||
The recommended hardware and software settings are intended to ensure optimum
|
SBC SWe for KVM Hypervisor – Server Hardware Requirements
Multiexcerpt | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| |||||||||||||||||||||||||||||||||||||||||
The following table lists the server hardware requirements.
|
BIOS Setting Recommendations
Ribbon recommends the following BIOS settings for optimum performance:
BIOS Parameter | Recommended Setting | Details |
---|---|---|
Intel VT-x (Virtualization Technology) | Enabled | For hardware virtualization |
Intel Hyper-Threading | Enabled | |
Intel Turbo Boost | Enabled | |
CPU Power Management | Maximum Performance | |
Sub-NUMA Clustering | Disabled | Only applies if it is present as an option on the server |
Example BIOS setting recommendations for HP DL380p Gen8 servers are shown below. For BIOS settings of other servers, refer to the respective vendor's website.
BIOS Setting Recommendations for HP DL380p Gen8 Servers
BIOS Parameter | Recommended Setting | Default Value |
---|---|---|
HP Power Profile | Maximum Performance | Balanced Power and Performance |
Thermal Configuration | Maximum Cooling | Optimal Cooling |
HW Prefetchers | Disabled | Enabled |
Adjacent Sector Prefetcher | Disabled | Enabled |
Processor Power and Utilization Monitoring | Disabled | Enabled |
Memory Pre-Failure Notification | Disabled | Enabled |
Memory Refresh Rate | 1x Refresh | 2x Refresh |
SBC SWe for KVM Hypervisor – Software Requirements
Multiexcerpt | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| |||||||||||||||
The minimum SBC SWe requirements for a KVM hypervisor environment are listed in the following table.
|
Downloading the SBC SWe Software Package
For more information, see Downloading the SBC SWe Software Package.
Info | ||
---|---|---|
| ||
Ensure Processors and VM configuration (CPUs, RAM, Virtual Hard Disk, NICs, and Bridge settings) are identical for an SBC SWe HA pair. |
Info | ||
---|---|---|
| ||
Do not change BIOS settings once they are applied on the server. |
KVM Configuration and Settings
Configuration | Settings | ||||||
---|---|---|---|---|---|---|---|
vCPU | Minimum 4 vCPUs required. Any number of vCPUs may be configured depending upon the call capacity requirements, but the number should be even (4, 6, 8, etc.) to avoid impacting performance. CPU resource reservation and pinning are required. | ||||||
vRAM | Reserve the memory based on call capacity and configuration requirements. Refer to benchmarking data for supported call capacities with different configuration limits. Memory resource reservation is required. | ||||||
Virtual Hard Disk | Set Hard Disk (virtual) size as 100 GB or more (based on requirements of retaining CDRs, logs, etc. for number of days). Note: Hard disk size cannot be changed after the SBC SWe software is installed. | ||||||
vNICs | Set number of virtual NICs as 4 (1-MGMT, 1-HA, 1-PKT0 and 1-PKT1).
|
Info | ||
---|---|---|
| ||
You can instantiate the SBC SWe in smaller-sized configurations that use limited memory and vCPU resources, if required. However, the limited resources place some restrictions on capacity and capabilities. Refer to Small SBC SWe Deployment Characteristics and Performance Metrics for Small SBC SWe ConfigurationsConfiguration Performance Metrics for more information. |