Add_workflow_for_techpubs
AUTH1UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26ca7f046c, userName='null'}
JIRAIDAUTHSBX-88903
REV5UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cb8305e9, userName='null'}
REV6UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cb8305e9, userName='null'}
REV3UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26c8c30172, userName='null'}
REV1UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26c8c30172, userName='null'}


Panel

In this section:

Table of Contents


Edit Rph Egress

This object determines how the SBC handles the ets and wps namespaces in the RPH (built by the SBC).

  1. Log on to the EMA as admin and navigate to All > Profiles > Services > Hpc Call Profile > Rph > Egress.

  2. The Egress window displays. Select a Hpc Call Profile from the drop-down list.
     

    Caption
    0Figure
    1Rph - Egress

    Image Modified



  3. The Edit Egress panel displays.
     

    Caption
    0Figure
    1Edit Egress

    Image Modified


    Caption
    0Table
    1Rph - Egress flags


    ParameterLength/RangeDefaultDescriptionM/O
    Valid Ets WpsN/ADont IncludeDetermines if the SBC includes or does not include namespaces other than ets and wps in the RPH (built by the SBC).
     - Dont Include (default)
     - Include
    O
    Non Ets WpsN/AIncludeDetermines if the SBC includes or does not include valid ets and wps namespaces in the RPH (built by the SBC).
     - Dont Include
     - Include (default)
    O





  4. Edit the values and click Save.


For more information on RPH handling, refer to SIP Resource Priority Header Support for HPC-GETS.

Pagebreak