Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Add_workflow_for_techpubs
AUTH1UserResourceIdentifier{userKey=8a00a0c86e9b2550016ec54396b5000a8a00a0c86820e56901685f374974002d, userName='null'}
JIRAIDAUTHSBX-113464118835
REV5UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cb8305e9, userName='null'}
REV6UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cb8305e9, userName='null'}
REV3UserResourceIdentifier{userKey=8a00a0c86af1a8d3016afe2f47e100088a00a02355cd1c2f0155cd26cb1f0553, userName='null'}
REV1UserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26c7480005, userName='null'}

Type: MAJOR MAJOR

Object ID1.3.6.1.4.1.2879.2.8.1.2.1.19.0.8
Alarm NamesonusCpLicenseManagerNoLicenseUsageDetected

Description

This trap alarm indicates that the License Manager has not collected license usage statistics for more that a day.

Repetition

Repeats for each occurrence.

Event Codes

EVENT_LICENSE_MANAGER_NO_LICENSE_USAGE_DETECTED

Instance Fields
  • sonusAlarmNodeID
,
  • sonusAlarmLevel
,
  • sonusAlarmSequenceId
,
  • sonusAlarmTime
,
  • sonusAlarmDescription
,
  • sonusServerIpAddress
,
  • sonusLicenseManagerLastCollectionTime
,
  • sonusLicenseManagerGraceDaysLeft

Action

Check the logs on the License Manager and correct the issues listed. This issue will be seen if no calls have been made on the system and no on/off licenses are present.

ImpactAfter the grace period expires, the SBC will not be able to process calls

If the SBC remains disconnected from the managing EMS/RAMP instance for an extended period of time, it will result in the SBC operating in an unsanctioned manner from a licensing perspective. Reconnect the SBC to the managing EMS/RAMP instance. Contact

Spacevars
0company
 Global Product Support for more information regarding the need for the SBC to remain in constant contact with the managing EMS/RAMP instance.

Clearing

automatic; sonusCpLicenseManagerLicenseUsageDetected