This section provides information on connecting media (packet) ports, HA ports, management ports, serial port and alarms ports and installing SFPs.

Installing SFPs

Warning

Ribbon-provided SFP modules must be used to guarantee proper operation of the external ports. Failure to follow this recommendation may cause permanent damage to the system.

The following SFP transceivers are compatible with

Spacevars
0series
in all Media and HA ports:

  • SBC-5XXX-SFPSM: GIG-E, SINGLE MODE, FIBER OPTIC TRANSCEIVER MODULE, LC, SMALL FORM PLUGGABLE (SFP), 10KM 1310NM, DMI
  • SBC-5XXX-SFPMM: GIG-E, MULTI-MODE, FIBER OPTIC TRANSCEIVER MODULE, LC, SMALL FORM PLUGGABLE (SFP), 300M
  • SBC-5XXX-SFPCOPPER: GIG-E, 1000 BASE-T SMALL FORM PLUGGABLE (SFP)

SFP transceivers must be installed in the Media and HA (if configured for HA) ports of each 

Spacevars
0series
server before making the fiber/copper connections.

  • Insert the SFP Gigabit Ethernet LC or SFP Gigabit Ethernet copper RJ-45 transceivers into SBC 5100/5110 media ports 0-1, SBC 5200/5210 media ports 0-3, as needed.
  • Insert the SFP Gigabit Ethernet LC or SFP Gigabit Ethernet copper RJ-45 transceivers into HA ports 0-1, as needed.
Note

The router(s) connected to the Media ports MUST support Gigabit speeds. Otherwise, the Gigabit Media ports will not be able to communicate with the router(s).

Follow these steps to install SFPs for the first time. To replace an SFP, see the CRU document SBC 5000 Series SFPs.

  1. Attach an Electrostatic Discharge (ESD) wrist strap (provided in the 
    Spacevars
    0series
    kit) using the ESD grounding point on the rear panel of the chassis (see Connecting Electrostatic Discharge Wrist Strap).
  2. Insert the Ribbon-approved SFP transceiver into the desired socket and ensure that the proper orientation when inserting, and that you will hear a click-in when the SFP is seated correctly.
  3. Connect/reconnect the fiber optic and/or CAT 5 cables, as appropriate, to media and HA ports.
  4. Verify LEDs above the part are flashing indicating link status and data activity.
  5. Verify port functionality using the CLI show status system commands once the SBC application software is installed and the system is up and running (for details, see show status systemrefer to Show Status System).
    1. Verify management and packet port functionality:

      Code Block
      languagenone
      > show status system ethernetPort 


    2. Verify HA port functionality:

      Code Block
      languagenone
      > show status system highAvailabilityPort 


Note

If an unsupported SFP module is inserted, an error message similar to the following displays:

PNPS: pkt1 SFP detected not supported by Ribbon! Turning pkt1 off!
PNPS: Replace pkt1 SFP with an approved Ribbon part to ensure NEBS. Replace the SFP modules to resolve issue.

Connecting Serial Port

When connecting a serial cable to the rear serial port of the

Spacevars
0product
server for communication with a host PC, refer to the figure below for the serial port location.

Caption
0Figure
1SBC Serial Port Connection

The following table lists the serial port settings for the host PC.

Caption
0Table
1Host PC Serial Port Settings


Serial Port Settings

Value

Baud

38400

Data bits

8

Stop bits

1

Parity

None

Flow Control

None


The DB9 serial cable pin-out is shown below.

Caption
0Figure
1Serial Cable DB9-F to DB9-M Pin-out

    



Caption
0Table
1Pin and Signal Type


PinSignal Type
1DCD
2RXD
3TXD
4DTR
5GND
6DSR
7RTS
8CTS
9RI



Caption
0Figure
1Null Modem Serial Cable

Pagebreak

Connecting Management Port

To establish the Management port connections, connect the CAT5e cable to the Mgmt 0 and Mgmt 1 ports. The CAT5e cable may be connected to a switch, router, LAN or WAN as per the customer requirements.

Connecting High Availability Ports

The physical connection between two 

Spacevars
0series
systems consists of a pair of GigE cables (Use the Single mode or Multi mode fiber optic CAT5e cable (NON-CROSSOVER TYPE ONLY), directly connected between each HA ports.

The HA connections provides both box-Level and port-level redundancy system. The HA pair system consists of four management ports; two ports each per system. When a switchover occurs, the logical management address follows the currently active server. For the Media ports, the MAC and IP addresses float (are replicated from active to standby on fail-over).

Include Page
Logical_management_address
Logical_management_address

Caption
0Figure
1Management and HA Port Connections for SBC 5100


Note

If using fiber SFPs for HA connections, both ends of an HA connection must use the same type. Connecting a single mode SFP to a multi-mode will not work.

Connecting Alarm Ports

Note

The Alarm port is not supported by the SBC 5000 series application software in this release.

The 

Spacevars
0series
ports, allow you to sense (Alarm In) and issue (Alarm Out) external signal. The Alarm Port utilizes a DB15 pin connector and supports 4 output alarms and 2 input alarms. You must create the remainder of the cable, wiring the appropriate sensor or alarm leads to the screw terminator on the connector. 


Caption
0Figure
1SBC 5000 Series Alarm Ports


The following table lists the Alarm port pin details and their descriptions.

Caption
0Table
1Alarm Port Pin-outs


Pin

Description

1

Minor Reset

2

Minor Reset Return

3

Major Reset

4

Major Reset Return

5

Critical Alarm Normally Open

6

Critical Alarm Normally Closed

7

Critical Alarm Return

8

Minor Alarm Return

9

Minor Alarm Normally Open

10

Minor Alarm Normally Closed

11

Major Alarm Normally Open

12

Major Alarm Normally Closed

13

Major Alarm Return

14

Power Alarm Normally Open

15

Power Alarm Return


Alarm Out Ports

Each Alarm Out port is a dry relay contact. Each contact will withstand up to 60 volts DC maximum when open, and will carry up to 1 ampere DC maximum when closed.

The following table lists the pin out for the Alarm Out port.

Caption
0Table
1Alarm Out Port Pin-outs


Pin

Signal

Power Out or Reset Condition

1

Alarm Out 1

Closed

2

Alarm Out 1 Return

 


3

Alarm Out 2

Open

Alarm Out 2 Return

 

5Alarm Out 3 Open
6

Alarm Out 3 Return

 


7

Alarm Out 4

Open
8

Alarm Out 4 Return

 



Alarm In Ports

Each Alarm In port is an isolated, current-sourcing sensor which expects to see an external dry contact connection open and close.

Note

No external voltage or current should be applied to the Alarm In ports.

For proper operation, the total external load (wiring plus dry contacts) on an Alarm In port must be less than 200 ohms. (Each Alarm In port can source up to 20 milliamperes DC of current maximum, and withstand a voltage drop of up to 7.5 volts DC maximum across an external load.)

Note

 Pin 1 is beside the Alarm In text on the module face plate.

The following table lists the pin-out for the Alarm In port.

Caption
0Figure
1Alarm In Port Pin-outs


Pin

Signal

Power Out or Reset Condition

1

Alarm In 1

 


2

Alarm In 1 Return

 


3

Alarm In 2

 


4

Alarm In 2 Return

 

 




Include Page
ESD_footnote
ESD_footnote

Pagebreak