Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Object ID1.3.6.1.4.1.2879.2.10.1.1.14.0.1

Description

This Trap alarm is generated when either pass-through or transcoded sessions fail to setup set up due to the lack of a valid session license, or if the total number of active sessions has reached the session license limits thereby unable to complete newer callslimit. As a result, new calls will fail.

Repetition

None

Event Codes

sonusAlarmNodeID
sonusAlarmLevel
sonusAlarmSequenceId
sonusAlarmTime
sonusAlarmDescription
sonusSessLicenseLimit

Instance Fields

sonusSessLicenseLimit

Action

 
Obtain additional session licenses.

Impact

Call failures due to sessions license unavailabilityCalls exceeding the session license limit are rejected.

Clearing

Automatic; sonusSbxCallRejectsDueToSessionLicenseClearNotification

...