Type: INFORMATIONAL

 
Object ID1.3.6.1.4.1.2879.2.10.1.1.12.0.5

Description

This trap alarm indicates that the service change handoff is received and is cleared  automatically by "sonusH248ScNotificationClear" notification after the association is established with the secondary MGC.

Repetition

None

Event Codes

  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId

Instance Fields

  • sonusAlarmTime
  • sonusAlarmDescription
  • sonusH248SigRemoteIpAddr
  • sonusH248SigLocalIpAddr
  • sonusH248SigScMethod
  • sonusH248SigMid

Action

None

Impact

Call failures may happen, if the VMG association is not established after handoff with secondary MGC.

Clearing

If the association is established with Secondary MGC, Automatic; sonusH248ScNotificationClear.

If the association is not established with Secondary MGC

 