Type: MAJOR
Description | This trap alarm indicates that a DSP core-dump was collected after a single DSP failure and subsequent successful reload. |
Repetition | None |
Event Codes | None |
Instance Fields | None |
Action | None |
Impact | The SBC successfully reloaded a failed DSP, restored active channels (if any) and collected a core dump in the background of the DSP failure event. |
Clearing | Manual |