  1. Connect your PC/Laptop via an Ethernet cable to the Field Service Port (FSP) at the back of 

    Spacevars
    0model5
    unit as shown in the image, and power up the 
    Spacevars
    0model5
    (if not already on).

    Caption
    0Figure
    1SBC 5400 PC to FSP

     

    Image Modified

     

  2. Verify that both link LEDs at the FSP are lit. If only the left LED is lit, your PC/laptop network adapter link speed may be set to 10 Mbps. Check the PC/laptop Device Manager, and if necessary set your PC/laptop link speed to 100 Mbps/Full Duplex.
  3. If your PC/laptop uses DHCP and Automatic Private IP Address setting is enabled (default setting), the PC/laptop will be assigned an IP address in the same subnet as the initial BMC IP; therefore proceed to step 5.  If your PC/laptop does not use DHCP, proceed to the next step to configure a static IP.
  4. From Control Panel, set your PC/Laptop IP address to 169.254.77.2, subnet mask to 255.255.255.0, and default gateway to 169.254.77.1.
    Windows 7 Path: Control Panel > Network and Sharing Center > Local Area Connection > Local Area Connection Properties > Internet Protocol Version 4 (TCP/IPv4) Properties.

     
    Caption
    0Figure
    1SBC 5400 LAN Properties

    Image Modified

     

  5. Anchor
    Step 5
    Step 5
    Type the pre-configured IP address 169.254.77.1 in a web browser (Firefox recommended. If you are using Internet Explorer, you must manually add "https://169.254.77.1" as a trusted site) to connect to the BMC web interface. The BMC GUI Login screen appears.
  6. Enter Username as “root” and Password as “superuser”. The SBC BMC main screen is displayed.
  7. Click Configuration > Network tab. The BMC Network Settings screen is displayed.

     
    Caption
    0Figure
    1SBC 5400 Network Configuration Screen

    Image Modified

     

  8. Enter the BMC IP Address, Prefix and Default Gateway network settings, then click Save to save the configuration.

     
    Caption
    0Figure
    1SBC 5400 Network Configuration Screen 2

    Image Modified

     

  9. Disconnect the laptop from FSP, and then connect the FSP Port to the router.
  10. Connect a PC to the IP network that can access the BMC IP address.
  11. Continue to Procedure 2 (below) to configure network management interfaces.

...

  1. Open a browser and enter the new BMC IP address to connect to the BMC web interface. The BMC Login window is displayed.

     
    Caption
    0Figure
    1SBC 5400 BMC Login window

    Image Modified

     

  2. Logon to the BMC using Username as “root” and Password as “superuser”. The SBC BMC main screen is displayed.

  3. Click the Configuration > Platform Management Network tab.

     
    Caption
    0Figure
    1SBC 5400 Platform Management Network Option

    Image Modified

     

    The Platform Management Network Settings screen is displayed.

     
    Caption
    0Figure
    1SBC 5400 Platform Management Network window

    Image Modified

     

  4. Configure the following network settings for all the four Management Interfaces 0, 1, 2 and 3. and then click Save:
    • IPv4 Address
    • IPv4 Address Prefix
    • IPv4 Default Gateway

...

  1. Check that port 22 is set to allow access to securelink.sonusnet.com.
  2. From same network as management IPs, open a browser and enter new mgmt. IP.
  3. Logon to EMA unit “A” using Username as “admin” and Password as “admin”. Upon initial login, you are prompted to change password. Change the password.
  4. Navigate to Administration > System Administration and select Secure Link from the navigation panel.

     
    Caption
    0Figure
    1System Administration > Secure Link

    Image Modified

     

  5. From the SecureLink window, enter DNS IP Address associated with your network and the assigned Registration Code (obtained from Sonus).
  6. Click Enable Gatekeeper Access.

     
    Caption
    0Figure
    1SecureLink - Enabling GateKeeper Access

    Image Modified

     

  7. Wait a minute or two for Gatekeeper access field to change to "enabled" before proceeding.

     
    Caption
    0Figure
    1SecureLink - GateKeeper Access Enabled

    Image Modified

     

  8. Click Test SecureLink Access to perform Host name look-up and Direct connectivity tests.

     
    Caption
    0Figure
    1SecureLink - Testing Secure Link

    Image Modified

     

  9. Observe "Passed" indication for both tests. Your SBC is now configured for SecureLink remote access!

     
    Caption
    0Figure
    1SecureLink Lookup Test Passed

    Image Modified

     

  10. If you have an HA configuration, return to Procedure 1. Configure BMC For Remote Access and repeat all steps in this procedure for the second 

    Spacevars