Object ID1.3.6.1.4.1.2879.2.8.1.2.1.5.0.33

Description

This trap alarm indicates that the CE/server NP temperature is reaching critical level. It is generated when the temperature is greater than or equal to 85oC.

Repetition

None

Event Codes

sonusAlarmNodeID
sonusAlarmLevel
sonusAlarmSequenceId
sonusAlarmTime
sonusAlarmDescription
sonusCpSystemServerName
sonusCpSystemAdminName
sonusCpSystemServerTemperatureSensorId
sonusCpSystemServerTemperature

Instance Fields

sonusCpSystemServerName
sonusCpSystemAdminName
sonusCpSystemServerTemperatureSensorId
sonusCpSystemServerTemperature

Action

Check NP temperature and Fan status

Impact

Server will shutdown if the NP temperature reaches critical level.

Clearing

Automatic; sonusCpSystemNPTempNormalNotification