This section provides information on the Sonus 

Spacevars
0model5
hardware platform specifications.

...

width24px

...

In this section:

...

Chassis

Sonus 

Spacevars
0model5
is a 2U rack-mounted chassis. The chassis can be front or center mounted in a standard 19 or 23 inch wide rack. At a high level, a fully populated 
Spacevars
0model5
system is comprised of the following key components.

...

Caption
0Figure
1SBC 5400 Chassis Front View

 Image Removed

Image Added

Rear View

Image Removed
Caption
0Figure
1SBC 5400 Chassis Rear View

 

Image Added

 

Caption
0Table
1SBC 5400 Hardware Specifications
3SBC 5400 Hardware Specifications
Front PanelRear PanelExpansion (Modular) StorageMemory Power Option
  • Status Indicators Front Panel LEDs
  • Single USB V2.0 interface
  • 4x100 Mb Management Ports with RJ45 connector
  • Media Ports (1x10Gb or 4x1Gb) with SFPs
  • Two 1 Gb speed High Availability Ports with SFPs
  • 1x100 Mb Single Field Service port with RJ45 connector
  • Locator LED
  • Alarm port with HD15 connector
  • Single serial craft DB9 port

Four DSP25 or one DSP20 modules

Minimum 480 GB SSD

32 GB RAM  AC or DC 

...

The front panel includes status indicator LEDs and a single USB 2.0 port.

 The SBC 5400 Front Bezel bezel LEDs shows the front panel LEDs with and without Bezel without bezel mounted on the front panel of 

Spacevars
0model5
.

...

Caption
0Table
1Front panel LEDs Description
3Front panel LEDs Description

 

Illustration

LED

Color

Description

1

Front Power

Amber/Green

Power status indicator of all voltages generated on the module:

  • Green = All Power on
  • Off = BMC Power on or chassis power is off
2

Front Status

Amber/Green

Module Status indicator

  • Green = Application is running
  • Amber = Application start up has not completed, or the application has been shutdown

  • Off = Application is not running
3Front ActiveAmber/Green

Module Redundancy State Indicator:

  • Green = Active and Protected
  • Amber = Active but unprotected

  • Off = Not Active
4

Front Alarm

Amber/Red

Module Critical/Major Failure Indicator:

  • Red = Critical Alarm
  • Amber = Major Alarm
  • Off = No Alarm Conditions

5

Front Locator

WhiteModule identifier indicator. On or blinking, depending on the "ipmitool chassis identify" command.
6

FanCtl LED*

Green

Fan module indicator:

  • Green = Fan module is working
  • Off = Fan module is not working
Note
iconfalse

This LED is visible only when the

Bezel

bezel is removed.

Rear Panel

The rear panel layout and LEDs are as depicted in the Rear Panel LEDs for SBC 5400 figure:

...

Caption
0Figure
1Rear Panel LEDs for SBC 5400

 Image Removed

Image Added

 

The Rear Panel Description table lists the Ethernet port LEDs. Each of the Management ports, Media ports, HA ports, and FSP port support the following LEDs.

Caption
0Table
1Rear Panel Description
3Rear Panel Description

Component

Cable Requirement

Description

Alarm Port

Customer supplied cable

Alarm contact via a single shielded male HD15 connector. A single alarm port is present in 

Spacevars
0model5
in SBC 5400 platform.
This software release does not support the Alarm Port.

Management Ports

CAT5e cable

Four copper Ethernet Ports which process Management traffic and perform protocol termination.

Locator

 

Module identifier indicator

Media Ports

Single mode or Multi mode fiber/copper CAT5e cable

Four copper SFP or fiber SFP ports for media and signaling traffic.

High Availability Ports

Single mode or Multi mode fiber/copper CAT5e cable (NON-CROSSOVER TYPE ONLY)

Two copper SFP or fiber SFP ports for redundancy synchronization traffic. The platform supports box level redundancy via communication paths provided by the external HA Ethernet ports.

Serial Port

Male DB9 connector

An RS-232 port used by BMC.

Field Service Port

Copper CAT5e cable

A single Field Service Port.

Power Input

 

Power Supply. The following are the descriptions of the power supply LED functions:

  • Off: No power input to the supply.
  • Amber: Power supply fault.
  • Blinking Amber: Main system power output fault.
  • Blinking Green: Standby power to BMC is ON but main system power is not enabled.
  • Solid Green: Both standby power to BMC and main system power are ON and OK.

...

  • Alarm contacts are provided on the outside of the chassis through a single shielded male HD15 connector.
  • A standard USB connector on the front of the chassis.
  • Front and rear jacks for standard ESD straps.
  • Cable management.