  1. Login to the BMC using the following credentials:
    Username: root
    Password: superuser

    Caption
    0Figure
    1BMC Login Screen

  2. On the BMC main screen, select the Remote Control tab. The Remote Control screen displays.

    Caption
    0Figure
    1Remote Control Screen

  3. Click Power Control (or select Server Power Control option from the navigation pane). The Power Control and Status screen displays.

  4. Select Power Off Server - Orderly Shutdown option and click Perform Action.

     

    Caption
    0Figure
    1Power Control and Status Screen

    Note
    titleNote
    This action will only power off the host side of the SBC; the BMC is still up as shown in the figure below.
    Caption
    0Figure
    1Powering Off SBC Server

  5. Select the Maintenance tab in the BMC GUI to enter the Maintenance screen.

    Caption
    0Figure
    1Maintenance Screen

    Note
    titleNote

    If the power was not shut down successfully as described in step 4, the following pop-up message displays. Complete the step 4 before proceeding.

    Caption
    0Figure
    1Power Off Message

  6. Click Enter Update Mode. The Update Mode confirmation dialog displays.

    Caption
    0Figure
    1Confirming Update

  7. Click OK. The Firmware Upload screen displays.

    Caption
    0Figure
    1Firmware Upload Screen

  8. Click Browse, and from the Open dialog, browse to and select bmc5X00_v2.1113.0-R0.rom firmware image. To determine the exact version, see the applicable release notes at SBC Release Information.
  9. Click Open. The chosen file displays next to the Browse button.
  10. Click Upload Firmware to upload the selected BMC image file.

    Caption
    0Figure
    1Uploading Firmware

     Image Modified

  11. An image verification dialog appears. Click OK to continue. 

    Caption
    0Figure
    1Verifying Image

    Image Modified

    Note

    Verify that the Existing Version and New Version fields in Firmware Verification section are different. If the versions are different, continue to the next step to start the upgrade. Otherwise, click Cancel to exit out of the upgrade. A confirmation message appears on the screen. Click OK to continue. The Cancel operation reboots the BMC and host server as it must come out of the Maintenance mode.

    Caption
    0Figure
    1Cancelling the Upgrade

    Caption
    0Figure
    1Cancelling the Upgrade Contd.



  12. Click Start Upgrade. When the warning dialog displays, click OK to continue.

    Caption
    0Figure
    1Warning Dialog

    Warning
    titleWarning
    Once the upgrade process starts, do not close the screen.
  13. The firmware upgrade process takes a few minutes to complete. The upgrade progress displays in the Flash Status screen.

    Caption
    0Figure
    1Flash Status Screen

    Image Modified

  14. Once the firmware upgrade completes, a confirmation screen appears.

    Caption
    0Figure
    1Firmware Upgrade Complete

    Image Modified

    Note
    titleNote
    Once the upgrade completes, BMC and host reboots automatically. Verify that the SBC starts and sync with its peer server before proceeding further.
  15. Close the BMC GUI.
  16. Clear the browser cache and login into the BMC GUI again.
  17. Log on to the BMC GUI again and verify the upgraded version in the System Information page.

    Caption
    0Figure
    1BMC New Version

...