Login to the BMC using the following credentials:
Username: root
Password: superuser
Caption | ||||
---|---|---|---|---|
| ||||
On the BMC main screen, select the Remote Control tab. The Remote Control screen displays.
Caption | ||||
---|---|---|---|---|
| ||||
Click Power Control (or select Server Power Control option from the navigation pane). The Power Control and Status screen displays.
Caption | ||||
---|---|---|---|---|
| ||||
Note | ||
---|---|---|
| ||
This action will only power off the host side of the SBC; the BMC is still up as shown in the figure below. |
Caption | ||||
---|---|---|---|---|
| ||||
Select the Maintenance tab in the BMC GUI to enter the Maintenance screen.
Caption | ||||
---|---|---|---|---|
| ||||
Note | ||
---|---|---|
| ||
If the power was not shut down successfully as described in step 4, the following pop-up message displays. Complete the step 4 before proceeding. |
Caption | ||||
---|---|---|---|---|
| ||||
Click Enter Update Mode. The Update Mode confirmation dialog displays.
Caption | ||||
---|---|---|---|---|
| ||||
Click OK. The Firmware Upload screen displays.
Caption | ||||
---|---|---|---|---|
| ||||
Click Upload Firmware to upload the selected BMC image file.
Caption | ||||
---|---|---|---|---|
| ||||
|
An image verification dialog appears. Click OK to continue.
Caption | ||||
---|---|---|---|---|
| ||||
Note |
---|
Verify that the Existing Version and New Version fields in Firmware Verification section are different. If the versions are different, continue to the next step to start the upgrade. Otherwise, click Cancel to exit out of the upgrade. A confirmation message appears on the screen. Click OK to continue. The Cancel operation reboots the BMC and host server as it must come out of the Maintenance mode. |
Caption | ||||
---|---|---|---|---|
| ||||
Caption | ||||
---|---|---|---|---|
| ||||
Click Start Upgrade. When the warning dialog displays, click OK to continue.
Caption | ||||
---|---|---|---|---|
| ||||
Warning | ||
---|---|---|
| ||
Once the upgrade process starts, do not close the screen. |
The firmware upgrade process takes a few minutes to complete. The upgrade progress displays in the Flash Status screen.
Caption | ||||
---|---|---|---|---|
| ||||
Once the firmware upgrade completes, a confirmation screen appears.
Caption | ||||
---|---|---|---|---|
| ||||
Note | ||
---|---|---|
| ||
Once the upgrade completes, BMC and host reboots automatically. Verify that the SBC starts and sync with its peer server before proceeding further. |
Log on to the BMC GUI again and verify the upgraded version in the System Information page.
Caption | ||||
---|---|---|---|---|
| ||||
...