Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • Spacevars
    0model5
    server is racked mounted, cabled and powered up.
  • Server names are known (i.e. “XYZSBC1a” and “XYZSBC1b” as an HA pair).

  • BMC, management and DNS IPs are known (use table below).

  • DNS registration code is known (use table below).

  • Router is configured and connected to SBC management ports.

  • Router can send traffic to public Internet.

  • User obtained from Sonus the unique registration code for each SBC unit.

  • User provided server name(s), mgmt. IP(s), and NTP IP to Sonus.

The following table depicts the information needed to install SecureLink, and is divided into three sections. You will use this information in the subsequent sections below.

  1. BMC Network
  2. Network Mgmt Interfaces
  3. DNS Configuration
Caption
0Table
1Prerequisites Table
 1) BMC Network2) Network Mgmt Interfaces3) DNS Configuration
Unit AUnit B Unit AUnit BUnit AUnit B
IP Address  Mgmt 0:    
  Mgmt 1:    
  Mgmt 2:    
  Mgmt 3:    
Prefix  Mgmt 0:    
  Mgmt 1:    
  Mgmt 2:    
  Mgmt 3:    
Default Gateway  Mgmt 0:  Registration Code:Registration Code:
  Mgmt 1:    
  Mgmt 2:    
  Mgmt 3:    

Procedure

Procedure

Perform the Referencing the above three configuration details, perform the following steps to install SecureLink for remote access:

...

The 

Spacevars
0model5
servers ships with pre-configured with IP address 169.254.77.1 to facilitate out of the box access to the BMC web interface. You must configure your PC/laptop IP address to be on this network so that it can communicate with the 
Spacevars
0model5
server.

  1. Connect your PC/Laptop via an Ethernet cable to the Field Service Port (FSP) at the back of 

    Spacevars
    0model5
    unit as shown in the image, and power up the 
    Spacevars
    0model5
    (if not already on).

    Caption
    0Figure
    1SBC 5400 PC to FSP

  2. Verify that both link LEDs at the FSP are lit. If only the left LED is lit, your PC/laptop network adapter link speed may be set to 10 Mbps. Check the PC/laptop Device Manager, and if necessary set your PC/laptop link speed to 100 Mbps/Full Duplex.
  3. If your PC/laptop uses DHCP and Automatic Private IP Address setting is enabled (default setting), the PC/laptop will be assigned an IP address in the same subnet as the initial BMC IP; therefore proceed to step 5.  If your PC/laptop does not use DHCP, proceed to the next step to configure a static IP.
  4. From Control Panel, set your PC/Laptop IP address to 169.254.77.2, subnet mask to 255.255.255.0, and default gateway to 169.254.77.1.
    Windows 7 Path: Control Panel > Network and Sharing Center > Local Area Connection > Local Area Connection Properties > Internet Protocol Version 4 (TCP/IPv4) Properties.

    Caption
    0Figure
    1SBC 5400 LAN Properties

  5. Anchor
    Step 5
    Step 5
    Type the preconfigured pre-configured IP address 169.254.77.1 in a web browser (Firefox recommended. If you are using Internet Explorer, you must manually add "https://169.254.77.1" as a trusted site) to connect to the BMC web interface. The BMC GUI Login screen appears.
  6. Enter Username as “root” rootand Password as “superuser”superuser”. The SBC BMC main screen is displayed.
  7. Click Configuration > Network tab. The BMC Network Settings screen is displayed.

    Caption
    0Figure
    1SBC 5400 Network Configuration Screen

  8. Enter the BMC IP Address, Prefix and Default Gateway network settings, then click Save to save the configuration.

    Caption
    0Figure
    1SBC 5400 Network Configuration Screen 2

  9. Disconnect the laptop from FSP, and then connect the FSP Port to the router.
  10. Connect a PC to the IP network that can access the BMC IP address.
  11. Continue to Procedure 2 (below) to configure network management interfaces.

...

  1. Open a browser and enter the new BMC IP address to connect to the BMC web interface. The BMC Login window is displayed.

    Caption
    0Figure
    1SBC 5400 BMC Login window

  2. Login Logon to the BMC using Username as “root” rootand Password as “superuser”superuser. The SBC BMC main screen is displayed.

  3. Click the Configuration > Platform Management Network tab.

    Caption
    0Figure
    1SBC 5400 Platform Management Network Option

     

    The Platform Management Network Settings screen is displayed.

    Caption
    0Figure
    1SBC 5400 Platform Management Network window

  4. Configure the following network settings for all the four Management Interfaces 0, 1, 2 and 3. and then click Save:
    • IPv4 Address
    • IPv4 Address Prefix
    • IPv4 Default Gateway

...

  1. Check that port 22 is set to allow access to securelink.sonusnet.com.
  2. From same network as management IPs, open a browser and enter new mgmt. IP.
  3. Login Logon to EMA unit “A” using Username as “admin” and Password as “admin”. Upon initial login, you are prompted to change password. Change the password.
  4. Navigate to Administration > System Administration and select Secure Link from the navigation panel.

    Caption
    0Figure
    1System Administration > Secure Link

  5. From the SecureLink window, enter DNS IP Address associated with your network and the assigned Registration Code (obtained from Sonus).
  6. Click Enable Gatekeeper Access.

    Caption
    0Figure
    1SecureLink - Enabling GateKeeper Access

  7. Wait a minute or two for Gatekeeper access field to change to "enabled" before proceeding.

    Caption
    0Figure
    1SecureLink - GateKeeper Access Enabled

  8. Click Test SecureLink Access to perform Host name lookup look-up and Direct connectivity tests.

    Caption
    0Figure
    1SecureLink - Testing Secure Link

  9. Observe "Passed" indication for both tests. Your SBC is now configured for SecureLink remote access!

    Caption
    0Figure
    1SecureLink Lookup Test Passed

  10. If you have an HA configuration, return to Procedure 1. Configure BMC For Remote Access and repeat all steps in this procedure for the second 

    Spacevars
    0model5
    unit. Then continue to the next step. (Be sure to use Unit B’s information from the Prerequisites Table).

Contact your Sonus representative to test remote connectivity to 

Spacevars
0model5
platform via SecureLink.