If this option is enabled, this timer starts counting when SUSPEND ISUP message is received in SIP MIME. The timer is cancelled upon receipt of RESUME ISUP messag

To View and Edit Suspend Resume Timer

On SBC main screen, go

...

to Configuration

...

 > System Provisioning

...

 > Category: Trunk

...

Provisioning >

...

 Trunk Group

...

 > Sip Trunk Group

...

 > Signaling > Timers > Suspend Resume Timer. The Suspend Resume Timer window is displayed.

The Suspend Resume Timer can be checked for each Address Context, for each Zone, for each Sip Trunk Group created or for all the Address Contexts, Zones and Sip Trunk Groups created. Use the drop-down box to select the desired Address Context, Zone and Sip Trunk Group.

The Edit Suspend Resume Timer window is displayed.

Caption
0Figure
1

...

SIP Trunk Group - Signaling - Timers - Suspend Resume Timer

...

Image Added

The following fields are displayed:

Caption
0Table
1

...

SIP Trunk Group - Signaling - Timers - Suspend Resume Timer parameters

Parameter

Description

State

 Administrative state of timer. 

...

  • Disabled (default)

...

  • Enabled

Value

The suspend-resume timer value, in seconds. The value ranges from 1 to 720 and the default value is 30.

Type

Type of ISUP message to apply timer against. 

...

  • Both (default)
  • User Type Only 
  • Network Type Only   

...

Make the required changes and

...

click Save

...

 at the right hand bottom of the panel to save the changes made.

...